AVTM246004 BITE 2/2P Rev 4 July 2011
30
Step Three: Scanning Test Information with the Wand (Optional)
Refer to page 89 for additional
information about bar coding.
After initialization, the screen on the
receiver
prompts you to
decide whether you want to scan the test location ID, ambient
temperature, and pilot cell temperature using preprinted bar
codes provided by Megger.
Y
WAND (Y/N)?
N
MENU
If you connect the wand before
powering on the
receiver
, the
receiver
automatically prompts
you to scan the location ID.
If you choose to use the wand, the scanned information is
stored in the
receiver
along with the results of the test. It is
important to note that the wand is optional and, although it
provides a quick and convenient way of recording information,
it is not needed to perform a test.
If You Do Not Want
to Scan Information
Using the Wand
If you do not have a wand or you do not want to scan
information about this test, press
on the
receiver
. The
key corresponds to the N (for NO) and instructs the
receiver
to bypass the scanning procedures.
The
receiver
then prompts you to decide whether you want to
split the strap. Proceed to Step Five: Splitting the Strap on
page 33.
If You Want to Scan
Information Using
the Wand
If you have a wand and you want to scan information about
this test:
The UP ARROW key
corresponds to the Y (for yes).
1.
Press
on the
receiver
.
The
receiver
prompts you to connect the wand.
CONNECT WAND!