M
AVTM246004 BITE 2/2P Rev 4 July 2011
42
Measuring the Next
Section of a
Sectioned Battery
String
If you have finished testing the first section of a sectioned
battery string and want to measure the next section:
1.
Press the Current ON/OFF switch on the BITE 2/2P
transmitter
.
This blocks the current from being applied to the battery
while the
transmitter
powers down.
2.
Connect the
current source leads
to the next battery
section.
NOTE
: If you are interrupted and need to leave the site
unexpectedly, simply shut down the
receiver
and
transmitter
.
The
receiver
will “remember” where you left off when you
return to finish the test.
F
WARNING
Do not remove the BITE 2/2P transmitter current source
leads from the battery until the BITE 2/2P transmitter is
powered off. Always disconnect the current source leads
from the battery before removing them from the J2
connector on the transmitter. Do not leave the BITE 2/2P
connected to the battery when not in use.
3.
Press the Current On/Off switch on the BITE 2/2P
transmitter
.
After the CURRENT READY light illuminates, the current is
applied to the battery and you can continue testing.
Test the section. Repeat the procedure as needed, depending
on the number of sections in the battery string.