M
AVTM246004 BITE 2/2P Rev 4 July 2011
88
Interpreting Error Messages
Condition
Display
Explanation
Low Current
Lo_A
Receiver screen display for
transmitter
current
measurement (I < 3.0 A)
High Current
Hi_A
Receiver screen display for ripple and
transmitter
current measurement (I > 15.0 A)
Over-range
OVER
Receiver screen display for dc terminal voltage,
impedance, and strap resistance
Low Battery
LOW BATTERY
Receiver screen display indicating low battery pack capacity
Over Voltage
OVER
VOLTAGE
lamp
The OVER VOLTAGE light illuminates when the
voltage across which the current source leads are
connected is greater than 275 Vdc. Section the
battery as described under Sectioning a Battery
System on page 49.
If the BITE 2 or BITE 2P Needs Repairs
Megger offers complete repair service and recommends that
its customers take advantage of this service in the event of
equipment malfunction. Please call 610-676-8500 and ask
for Customer Service to obtain an RA #, then ship to:
TEL: 610-676-8500
Megger
ATTN: Repair Department
Valley Forge Corporate Center
2621 Van Buren Avenue
Norristown, PA 19403 U.S.A.
It is best if you return the entire instrument, including leads,
to help us find the source of the problem. Many times the
problem appears to be the
transmitter
, but the problem is
eventually found to be in the
receiver
. Please indicate all
pertinent information, including problem symptoms and
attempted repairs. Equipment returned for repair must be
shipped prepaid and insured and marked for the attention of
the Repair Department.