Page 221 of 226
Version: 3.3.5
– DR05 – 23.03.2017
Restore factory settings
27.2
Follow the steps outlined below to reset the industrial router to the factory settings:
IMPORTANT:
You should first
back up
your configuration. Once you have carried out these
steps, your previous settings will no longer be available.
1. Switch on the device
2. Wait until the
Rdy
LED
blinks
3. Press and hold the dial-out button until the
Fc4
/ TxD2 LED lights up
4. Press the dial-out button again (
Fc3
/ RxD2 lights up)
5. Press the dial-out button again (
Fc2
/ TxD1 lights up)
6. Finally press the dial-out button one last time
The custom configuration is then deleted, the industrial router is reset to the factory settings and
can be reconfigured.
IMPORTANT:
The IP address of the industrial router is reset to 192.168.0.100. The computer
’s
network settings must be changed accordingly.