Page 195 of 226
Version: 3.3.5
– DR05 – 23.03.2017
Input 1 .... 4 tabs
Each input can be separately configured. Select the input to be configured by clicking the
corresponding tab.
Enable
The input is enabled by checking the box. This is how you determine whether the input in
question is to be enabled (
“activated”).
Query on
Set the input level for the industrial router in this drop-down field. The available signal lev-
els are 1 and 0.
Action
There are three possible actions:
□
□
SMS (only available at
mbNET
variants with modem!)
□
System Reboot
□
Internet-SMS
Text
Enter the text to be sent to the specified email address in this input field.
The following special characters are permitted in the text:
Ä Ü Ö , ; . : - _ # + * ~ ^ ° ! ( ) = ? § $ % & / < >
Email/Mobile
Phone
Enter the email address or phone number* to which the industrial router should send the
text when the input is activated and the relevant signal level has resulted in the action be-
ing initiated.
* Up to three mobile phone numbers are possible - separated by semicolon or comma.
current State
You can read off the current state at the inputs via the LED icons at the bottom of the
screen. Gray indicates state 0, green indicates state 1.
Multiplex inputs
21.2.1
Brief description
There are four digital inputs on the mbNET. An action assignment (number) can be communicat-
ed serially via three of these inputs (2-4), i.e. one input is STROBE, one is IMPULS_x1 and one
is IMPULS_1x. The pulse at IMPULS_x1 (one digit) and IMPULS_1x (tens digit) can be counted
with a rising edge at STROBE. The action is executed in accordance with the entered action with
a falling edge at STROBE.
Graph
The action
52
is initiated in the sample graph.