Digital outputs
21.3
Click
Alarmmanagement
in the navigation bar,
followed by
Output
.
The following screen for configuring the two avail-
able digital outputs is then displayed. The outputs
can be separately configured using the two tabs.
The input and drop-down fields are described on
the following pages.
Label
Description
Output 1 Out-
put 2
Each output can be separately configured. To configure an output, select the corresponding
tab.
Function
You can chose between the following settings using the drop-down field:
Off
Select this setting if you do not want to evaluate the outputs for possible switching opera-
tions.
On with Malfunction
Select this setting if the corresponding output of the industrial router is to be set to signal lev-
el 1 in the event of a malfunction.
On by Internetconnection
Select this setting if the corresponding output of the industrial router is to be set to 1 in the
event of an active Internet connection. For example, an active Internet connection can then
be indicated by an LED connected at output O1 or O2.
State
Switch On
or
Switch Off
This button can be used to switch the currently selected output on and off. The text
Off
or
On
above the button shows the current output state in the same way as the LED icons under
current State
.
Green LED icon:
Signal level 1 at output
Gray LED icon:
Signal level 0 at output