74
Maxxyz
We can now select any or all of these fixtures and make the desired changes. We can also add
fixtures to the programmer using either conventional fixture selection methods or by using the
“Load” function described below.
Once you have made your changes, you can press
Update Enter
or
Update Update
to update
the cue the original information was taken from. For more information on the Update function,
please see “Update” on page 81.
L
O A D I N G
T H E
P
R O G R A M M E R
U S I N G
L
O A D
The “Load” command is extremely powerful and can be used to load complete groups and cues
or attribute groups or individual attributes of selected fixtures. Further, “Load” allows you to clone
the attribute values from one fixture to another fixture of the same type. Understanding how the
“Load” function performs is necessary in order to get the most out of the Maxxyz console. “Load”
differs from “Edit” in that where “Edit” will read information on attributes that have been recorded
with values in them, by default “Load” reads
all
of the specified base value attributes, whether
they are at a value or not.
12
If one or more of the attributes that is read by a “Load” function is at
a level (for example the attribute is in an active cue), then that value will be loaded into the
programmer as well.
T
HE
L
OAD
O
PTIONS
W
INDOW
To use the Load Options window and filters, employ the following steps:
1 Press
Load
2 Set your filters as desired
Press
Enter
The Load Options window contains several buttons that are broken down into five categories:
12. For an explanation of “base values,” please see“The Record Options Window” on page 86.
Load Options
Normally used in Record to determine how attributes in the
programmer are saved to cues, the “Merge” and “Replace” buttons
have the same identical function in the Load Options window. That is
to say, attribute values will always be merged into the programmer.
Clone Options
These options determine which attributes are uses in a cloning
operation
Extra Filtering
In conjunction with the other filters, these filters determine what types
of attributes will be added
Filter
This group of filters acts to filter out specific attribute groups
Default
These two buttons allow you to change the “default” behavior of Load
options window.
Summary of Contents for Maxxyz
Page 1: ...Maxxyz user manual For Use with Software Version 1 3 78 ...
Page 8: ...8 Maxxyz ...
Page 154: ...154 Maxxyz ...
Page 155: ...Appendix 3 Wiring Charts 155 ...
Page 156: ...Appendix 3 Wiring Charts 156 ...
Page 160: ......