214603
434
Revision A
Symptom
Problem
Solution
Reference
Excessive noise
from drive system
Faulty pump or motor
Contact Dealer.
Contact Dealer
Excessive noise
from drive system
Air in system
Check lines for leakage.
—
Excessive noise
from drive system
Hydraulic line clamps loose
Tighten clamps.
—
Hydraulic oil filter
leaks at seal
Not properly tightened
Tighten filter element.
Servicing the Lift
Filter, page 392
Hydraulic oil filter
leaks at seal
Damaged seal or threads
Replace filter or filter head.