Figure 3.96: Swath Compressor Switch
9.
Press switch (B) on console to raise swath compressor.
•
CALIBRATING SWATH is displayed on upper line.
•
FORM UP and flashing HOLD is displayed on lower
line until system has completed reading signal with
swath compressor fully raised.
•
SWATH FORM UP and DONE (with buzzer) is
displayed on lower line when complete.
•
SWATH SENSOR CAL is displayed on upper line.
•
PRESS SWATH DOWN is displayed on lower line.
10. Press switch (A) on console to lower swath compressor.
•
CALIBRATING SWATH is displayed on upper line.
•
FORM DOWN and HOLD is displayed on lower line.
•
SWATH FORM COMPLETE flashes for 2 seconds
on lower line (with buzzer) when calibration is
finished.
1009066
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 3.97: CDM Programming Buttons
11. Press PROGRAM (A) to exit programming mode or
press SELECT (C) to proceed to next windrower
setup action.