![background image](http://html.mh-extra.com/html/macdon/m205/m205_operators-manual_685753409.webp)
214603
389
Revision A
Installing Charge Oil Filter
NOTE:
For charge oil filter replacement part number, refer to
8.2.4 Filter Part Numbers, page 462
1006247
A
Figure 5.186: Charge Oil Filter
1.
Clean the gasket surface of the filter head.
2.
Apply a thin film of clean oil to the filter gasket.
3.
Screw the new filter (A) onto the mount until the gasket
contacts the filter head.
4.
Tighten filter an additional 1/2 turn by hand.
IMPORTANT:
Do
NOT
use a filter wrench to install oil filter.
Overtightening can damage gasket and filter.
5.
Check hydraulic fluid levels and add fluid if needed.
Refer to
5.10.1 Checking and Filling Hydraulic Oil, page
Return Oil Filter
The return oil filter filters the oil in the header drive systems and should be changed after the first 50 hours of
operation, and then at 500 hour intervals. The return oil filter is a part of the hydraulics package required to run a
draper or auger header and is
NOT
present in a windrower unless this package is installed.
To change the return oil filter, refer to the following procedures:
•
Removing Return Oil Filter, page 389
•
Installing Return Oil Filter, page 391
Removing Return Oil Filter
The return filter is only installed on windrowers that are configured for auger and draper headers.
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and
remove the key from the ignition before leaving the operator
’
s seat for any reason.
1.
Stop the engine and remove the key.
2.
Open the left cab-forward side maintenance platform. Refer to
Summary of Contents for M205
Page 3: ...Declaration of Conformity 1025029 ...
Page 4: ...1025030 ...
Page 20: ......
Page 440: ......
Page 462: ......
Page 511: ...windshield wipers 56 INDEX ...
Page 512: ......