49
The
IxV
is operating quite similar, but it is useful for ring notification. You can configure that
which phone numbers must the device ringin gin case of input line changes.
IVSMS
parameter
–
in case of unsuccessful calling/ringing the SMS text message sending
can be allowed.
The
IxON
parameter is used for SMS messaging for the input status, when the signal level is
ascending from low
high, while the
IxOFF
is for the descending value from high
low
(recovery).
SMSFWD
–
forwarding only messages in SMS text messages to the phone number #1 (the
mobile provider SMS notifications and SMS commands will be not forwarded).
ISABEVENT
–
in case of a sabotage event or wire cut the forwarded CID code can be
defined.
In case of a sabotage, wire cut, the SMS message can also be configured by the
ISABON
parameter. The recovery message by the
ISABOFF
definition.
If you’ve changed one of the listed parameter values, then the program will highlight the
changed value lines by
bold
. For sending the listed parameter values for the device
(regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At the end of the parameter sending, the device is
restarting by using the new settings.
Output settings
For
configuring the siren/bark and output operation
of the
Output Settings
parameter
group at the
Device Type
. Then the program will load the related parameters.
The output control is deactivated in this mode by default, then leave the
OUTMODE
value
on
Default
value.
If you are attempted to use and switch the siren then allow the input line alarm event to the
siren by the
SIRENOUT
parameter (in case of alerting, the siren will be turned on). The
SIRENDEL
defines the recovery time for the output (the siren will be turned off (muted)
after this defined interval).
For alarm system
arming or disarming
applying the „
bark”
sound can
enabled
by the
SIRENBARK
parameter.