53
Input line’s Contact ID settings
For
configuring the input line’s event trans
mitting
let’s open the
GPRS Input Parameters
view at the
Device Type
. Then the program will load the related parameters.
All detected and received signals and events of the
Easy 2
input lines are stored in a puffer
with their timestamps, where 32 events can be stored temporary by the system. These will
be transmitted/forwarded by the device through the defined network channel (GSM or GPRS
connection) to the configured IP address. Then by the handshake communication reply
message the buffered event will be deleted after its transmission. When the puffer is full, the
next event will be ignored.
The device tries to signalling the incoming events through GPRS connection to the primary IP
address. In case of unsuccessful sending (e.g. outage or fall of the primary IP address or a
network trouble), then after some delay it retries to send. If it is also unsuccessful, then it
tries to send the events to the secondary IP address. It it will not success then it drops the
event.
You have to
enable
the
IOGPRS
param
eter for transmitting the input line’s event and status
changes.
For monitoring a sabotage switch or further sensors, the CID event code must be defined at
the
IxEVENT
parameter, with the partititon number (
IxPART
), zone (
IxZONE
). (The
’
x
’
means the number of the input line in the name of the parameter).
Here you can define values only for the input line nr. #1 and #2. The IO-expansion settings