8
Signal levels:
Input high signal level:
5-24V
Input low signal level:
0-1V
Current in active status (for the Easy 2 inputs):
0.3-3mA
Current in active status (for the further Easy 2 IO inputs):
1-12mA
In case of using the
Easy 2 IO
-expander board, further 6 pcs of inputs are available (IN3..IN8),
which has the same operation and configuration possibility as listed here above.
When the input were activated (IN1, IN2) the
IN1, IN2
titled LEDs are signing the active
(closed) status during the operation, with the proper light and colour. See LED signals part.
The device has 2 input lines (IN1, IN2). They can be configured seperately to operate as a
voltage or contact mode for the input. These settings can be setup with the jumpers besides
the IN1, IN2 input line’s terminal blocks.
Connecting the relay output
One switchable output device can be connected to the relay output (OUT) of the mainboard),
according to the next figure. Connect the cable wire pair to the
OUT
title output line
’s
terminal
block (by sliding the companion piece and inserting the stripped wire pair, then fixing the
screws).
Mode
Contact
Voltage
Not inverted
NO (Normal Open)
Inactive mode: contact
opened
Active mode: contact closed
High active
Inactive mode: 0…1V
Active mode: 5
…24V
Inverted
NC (Normal Closed)
Inactive mode: contact closed
Active mode: contact opened
Low active
Inactive mode: 5
…24V
Active mode: 0…1V