77
Standalone Alarm System specific commands
–
Arming/Disarming
Command
Description
ARM
Arming the alarm status of the
Easy 2
(activates the arming)
DISARM
Disarming the alarm status of the
Easy 2
Gate opening, remote output control specific commands
Command
Description
GATE
or
CONT
or
CTRL
For affection of the command the added new phone number
will be recorded to the contact list into the argumented
position.
Values:
<n> position in the contact list (1
–
125).
In case of ’0’ the
current number will be deleted.
The
phone number
value can be added at here.
<phonenumber>
- the
phone number
value can be added
here. When it is already exists or the memory is full, then
there is no affection.
GATERM
Hatására a megadott sorszámú hívószám
törlődik a listából.
Value:
<telefonszám>
sequence number of the phone
number in the contact list
(1-125)
When executing this command the given phone number will be
deleted from the contact list.
OUTON
Gate opening
in Bi-stable mode: Relay contact will be closed (shortened)
in Mono-stable mode: Starts the timing
OUTOF
or
OUTOFF
Gate closing
in Bi-stable mode: Relay contact will be opened
in Mono-stable mode: Stops the timing
7.4 Examples for SMS command parameters
According to the SMS text message format standard, in one SMS message command you can
use max. 158 characters can be used in one SMS message.