65
For
gate opening, controling the output line
–
to remotely switch by SMS text message or a
voice call/ringing
–
change the
OUTMODE
value to
Gate
.
The output has two peration mode: a mono-stable and a bi-stable. The mode can be
configured by the
OUTHDELx
parameter. It holds on the output until the configured
interval, then it switches off.
When its value is:
0 or not defined: it is in bi-stable mode
1-
86400 (seconds): it’s in mono
-stable mode.
for the defined interval, it will hold the output on, then it will switch it off.
In mono-stable mode the output will be in standby (the relay contacts are opened) until a
trigger event will be occured. In case of a trigger the output relay will close (shortened),
then after a pre-defined delay interval automatically recovers to stand-by position.
During the delay interval when a trigger comes then the timing will be restarted (e.g. for
restartable mono-stable multivibrator).
In case of parameter value ’0’ the output operates in normal mode, then it will not switch
back.
In Bi-stable mode there is no delay. From the opened or closed standing positions the relay
can be switched or changed its position in case affect of the appropriate trigger.
The trigger event can be also for mono-stable and bi-stable modes the
OUTON
and
OUTOFF
command value or ringing (e.g. gate opening).
By the
GATESMS
parameter you can
enable
that the
gate opening events will be notified to
the phone number where the remote control were initiated from. The
GATEON
defines the
message for the gate opening event, and the
GATEOFF
it the gate closing event message.
If you’ve changed one of the listed parameter values, then the program will highlight the
changed value lines by
bold
. For sending the listed parameter values for the device
(regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At the end of the parameter sending, the device is
restarting by using the new settings.
IO-expansion settings (for input line nr. #3-8, and output line nr. #2-4)
For configuring the parameters of the
IO-expansion
open the
External IO
parameter
group
at the
Device Type
. Then the program will load the related parameters.