45
Then open the
IP-GPRS Service
parameter group at the
Device Type
. Then the program
will load the related parameters.
At the
SERVER1
parameter fill the primary IP address of the IP-receiver and the
PORT1
value for the port number. Setup the secondary IP address to the
SERVER2
and its port to
the
PORT2
(if it is also necessary).
Change the
IPPROTO
protocol’s format to
TCP
and the
SWPROTO
communication format
to
Enigma
which means a standard Contact ID protocol. (The
M2M
format means the
modified ContactID protocol, which can only be used with the following IP receivers or
remote dispatcher softwareas Enigma II, Enigma IP2 receiver devices, Alarmsys and SIMS
software).
If
you’ve changed
one of the listed parameter values, then the program will highlight the
changed value lines by
bold
. For sending the listed parameter values for the device
(regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At the end of the parameter sending, the device is
restarting by using the new settings.
Input line’s
Contact ID settings
All detected and received signals and events of the
Easy 2
input lines are stored in a puffer
with their timestamps, where 32 events can be stored temporary by the system. These will
be transmitted/forwarded by the device through the defined network channel (GSM or GPRS
connection) to the configured IP address. Then by the handshake communication reply
message the buffered event will be deleted after its transmission. When the puffer is full, the
next event will be ignored.