within the spacer’s cavity, which also indicates the temperature of the adjacent windings. The figure below
illustrates a sample probe tip mount.
Instructions for constructing and installing a radial spacer are provided in the next section.
Probe Tip Installation — Core Form Transformer
Radial Spacer Design
To construct a radial spacer from an EHV Weidmann Nomex
®
transformer board or equivalent, use
2 mm (0.08 in) thick TIV material (shown below).
Modified Radial Spacer
Note:
Refer to Section 12.1
for a list of suppliers that can provide materials
used for modifying the radial spacer.