MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-316
Computer Telephony Integration (CTI) Link
3
CTI Link Programming Errors
3
During the programming of the CTI link, entering an inappropriate extension
number can give you an error message. This section contains displays of each
screen and information about what to do if the screen appears.
System Not in Hybrid/PBX Mode
3
This message appears if the communications system is not in Hybrid/PBX mode.
CTI links cannot be used with communications systems operating in Key mode or
Behind Switch mode.
Extension Selected Not on MLX Port Module
3
This message appears if you have chosen an extension that is not on an MLX
Port Module. CTI link extensions cannot be programmed on tip/ring or analog
multiline extension module ports. You must chose an extension that is on an MLX
port module (008 MLX or 408 MLX).
CTI Link Extensions:
Extension xxxx Failed.
System Not in
Hybrid/PBX Mode.
Exit
CTI Link Extensions:
Extension xxxx Failed.
Not on MLX Port Module.
Exit