Programming Procedures
3-15
Basic System Operating Conditions
3
Set System Date
3
The System Date feature allows you to set the month, day, and year that appear
on MLX display telephones and on Station Message Detail Recording (SMDR)
reports.
NOTES:
■
If you plan to use the SMDR feature, make sure the current date is set.s
■
In Release 6.0 and later systems, where a MERLIN LEGEND
Communications System switch is networked in a private network with
one or more MERLIN LEGEND Communications System switches or
with one or more DEFINITY
®
Communications Systems, SMDR reports
may report outgoing calls using more than one call record (for example,
for tandem calls), depending upon how SMDR is programmed and how
calls are routed. Therefore, if SMDR is reporting outgoing calls and
users are employing private network lines to make these calls, ensure
that the system date and time are set accurately on each system that
carries these calls. As you examine call reports, you may need to be
aware of time zone differences among networked system locations.
Summary: Set System Date
3
Programmable by
System Manager
Mode
All
Idle Condition
Not required
Planning Form
1, System Planning
Factory Setting
01-01-00
Valid Entries
Month: 01 to 12
Day: 01 to 31
Year: 00 to 99
Inspect
No
Copy Option
No
Console Procedure
System
→
Date
→
Drop
→
Dial current date (Month:
01–12; Day: 01–31; Year: 00–99)
→
Enter
→
Exit
PC Procedure
→
→
7
+
2I
→
Type current date (Month:
01–12; Day: 01–31; Year: 00–99)
→
→