MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-87
Lines and Trunks
3
u
Block Procedure
3
Console/Display Instructions
Additional Information
PC
1.
Specify the block of 20 lines associated with the 20 line buttons on the system
programming console.
Select:
Lines
01–20
Lines
21–40
Lines
41–60
Lines
61–80
2.
Assign the LS-ID Delay to the appropriate lines/trunks.
Toggle the green LED on or off as required:
On = assign the LS-ID Delay
Off = remove the LS-ID Delay
3.
Return to the System Programming menu.
Select
Exit
twice.
Clock Synchronization
3
NOTE:
The following information is for planning clock synchronization in systems
that are not part of a private network. For planning clock synchronization in
a private network configuration, see the
Network Reference
.
Use this procedure to specify the primary, secondary, and tertiary clock source. A
clock source may be either a 100D module or a port on an 800 NI-BRI module.
See the
Feature Reference
for more information about the appropriate setting. If
the clock is taken from a 100D module, you can also specify whether the clock is
synchronized to the outside endpoint (loop) or to the clock reference source
(local).
NOTE:
This procedure is necessary only if your system includes an 800 NI-BRI
module or more than one 100D module.