MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming with SPM
2-70
Upgrading the System
2
Table 2-13.
Programming Needed after Upgrade to Release 5.0
Feature
Sequence
CTI Link
This is a Maintenance step. Start the procedure from
the Main Menu, not the System Programming screen.
Busy-out the board first:
Menu
→
Maintenance
→
Slot
→
Dial slot no.
→
Enter
→
Busy-Out
→
Yes
Program the CTI link (the switch must be in
Hybrid/PBX mode):
AuxEquip
→
CTI
Link
→
Dial extension no.
→
Enter
→
Exit
→
Exi
t
This is a Maintenance step. Start the procedure from
the Main Menu, not the System Programming screen.
Restore the slot:
Menu
→
Maintenance
→
Slot
→
Dial slot no.
→
Enter
→
Restore
→
Yes
NOTE:
If the MLX module containing the CTI link is the first module, use the
SPM program to busy-out the slot.
Calling Group Alarm
Thresholds
Extensions
→
More
→
Grp
Calling
→
Queue
Alarm
→
Dial calling group ext. no
.→
Enter
→
Alarm
Threshold
1
,
Alarm
Threshold
2,
or
Alarm
Threshold
3
→
Drop
→
Dial no. of calls
→
Enter
→
Exit
→
Exit
HotLine
Extensions
→
More
→
More
→
HotLine
→
Dial HotLine ext. no.
→
Enter
→
Exit
→
Exit
Calling Group Hunt
Type
Extensions
→
More
→
Grp
Calling
→
Hunt
Type
→
Dial calling group ext. no.
→
Enter
→
Circular
,
Linear
, or
Most
Idle
→
Enter
→
Exit
→
Exit
→
Exit
Group Calling Delay
Primary
Announcement
Extensions
→
More
→
Grp
Calling
→
DelayAnnce
→
Dial calling group ext. no.
→
Enter
→
Primary
Announcement
→
Enter Extension no. of
announcement device
→
Enter
(to program another
announcement device) or
Exit
(to end
procedure)
→
Exit