Installation
65
Other Auxiliary Outputs
The LCR 600 provides three open-drain transistor auxiliary outputs for different external devices–such as
pump controls and additive injectors. The schematic to the right identifies the J13 terminals where the
auxiliary outputs can be connected to the LCR 600.
Disconnect Power
Disconnect the power before working on the CPU board.
Auxiliary Output 1 (Out 1)
This signal has four output settings: Off, On, On During Delivery, and Monitor Flowrate.
Auxiliary Output 2 (Out 2)
This signal has three output settings: Off, On, On During Delivery, and Flow Direction.
Pulse Output (Out 3)
This output represents the gross delivery quantity for uncompensated deliveries or the net delivery
quantity (for compensated deliveries). This output is a real time 50/50 duty cycle representing the least
significant digit of the LCR 600 totalizers.
Auxiliary Output Settings
To select the Auxiliary Output settings, refer to the
LectroCount LCR 600 Setup and Operation
manual.