Installation
35
3. Lower the LCR 600 on to the bracket, and securely fasten using the four bolts (¼" x ¾") provided.
Star Gear and Drive Fork
When the register is lowered onto a Neptune meter, make sure the drive fork is not pressed against
the star gear on the meter. There must be a small gap between these two parts. To lower the star
gear, loosen the set screw on the side of the star gear. Failure to do so will eventually damage the
internal pulser and/or the meter gear train.
Apply Anti-seize
Apply anti-seize to all bolt threads to ensure easy removal at a later date.
Mount the LectroCount LCR 600 on previously temperature
compensated Neptune meters
1. Place the shaft adapter on the pulser drive shaft under the LCR 600.
2. Place the cotter pin through the hole, and bend open the ends of the cotter pin.
3. Pass the other end of the shaft adapter through the flange assembly and the weather plate.
4. Loosely bolt to register.
5. Place the drive fork and extension piece on the shaft using two more cotter pins.
6. Bolt the flange to the meter and tighten all bolts.