Installation
Neptune Meters
Remove Existing Registration Equipment
Follow these steps:
1. Depressurize the meter completely. See the Warnings in
.
2. Remove the mechanical register from the meter.
3. Leave the star-shaped gear and the two square-head studs.
4. Remove the bellows from the front of the meter.
5. Remove the compensator.
Mount the LectroCount LCR 600
Follow these steps:
1. Install the drive fork and extension piece (pictured below) on the pulser drive shaft located on the
bottom of the LCR 600.
2. Install the bracket on the meter, and fasten with the bolts provided in the kit.