Installation
To wire optical air and vapor eliminators to the LCR 600:
1. Attach cable glands and/or conduit connectors to the S3 solenoid valve, the optical sensor, and the
LCR ports.
2. Thread the 20 AWG wires through a piece of weatherproof conduit cut-to-length from the S3
solenoid to a LCR 600 port.
3. Run the weatherproof conduit between the S3 solenoid operated valve and the LCR 600 housing.
Pull the wires through the ports, and tighten the connectors. Liquid Controls recommends running
the optical sensor wire through weatherproof conduit as well.