Installation
49
Solenoid Operated Valve Cables
The 81527 solenoid operated valve (3-way LPG solenoid) has 3 cables potted into the housing. All
other solenoid operated valves on Liquid Controls valves use cable assembly 81859, which has 2
cables.
Valves with 110VA C Solenoids
In order for the LectroCount LCR 600 to control valves with solenoids on 110 VAC circuits, you must
install a relay switch on the positive leg of the solenoid’s circuit.
Relay switch specifications:
·
Switch: SPST (single pole, single throw)
·
Switch Position: Normally open
·
Contact Rating: Greater than maximum current of solenoid
·
Voltage: +12 VDC