| Monitoring the Switch
Displaying LLDP Information
– 271 –
◆
Auto-negotiation Status
– Auto-negotiation status identifies if auto-
negotiation is currently enabled at the link partner. If Auto-negotiation
is supported and Auto-negotiation status is disabled, the 802.3 PMD
operating mode will be determined the operational MAU type field value
rather than by auto-negotiation.
◆
Auto-negotiation Capabilities
– Shows the link partners MAC/PHY
capabilities.
◆
MAU Type
– The operational MAU type of the sending device.
W
EB
I
NTERFACE
To display information about LLDP-MED neighbors, click Monitor, LLDP,
LLDP-MED Neighbors.
Figure 140: LLDP-MED Neighbor Information
D
ISPLAYING
LLDP
N
EIGHBOR
P
O
E
I
NFORMATION
Use the LLDP Neighbor Power Over Ethernet Information page to display
the status of all LLDP PoE neighbors, including power device type (PSE or
PD), source of power, power priority, and maximum required power.
P
ATH
Monitor, LLDP, PoE
P
ARAMETERS
These parameters are displayed:
◆
Local Port
– The port on this switch which received the LLDP frame.
◆
Power Type
– Shows whether the device is a Power Sourcing Entity
(PSE) or Power Device (PD). If the Type is unknown it is represented as
“Reserved.”
◆
Power Source
– The Source represents the power source being
utilized by a PSE or PD device.
For a PSE device, it can run on its Primary Power Source or Backup
Power Source. If it is unknown what power supply the PSE device is
using, this is indicated as “Unknown.”
For a PD device, it can run on its local power supply or use the PSE as a
power source. It can also use both its local power supply and the PSE.
Summary of Contents for GEP-5070
Page 1: ...GEP 5070 48 GE PoE Plus 2 GE SFP L2 Managed Switch User Manual V1 0...
Page 2: ......
Page 4: ......
Page 6: ...ABOUT THIS GUIDE 6...
Page 18: ...FIGURES 18...
Page 20: ...TABLES 20...
Page 22: ...SECTION I Getting Started 22...
Page 34: ...SECTION II Web Configuration 34...
Page 217: ...CHAPTER 4 Configuring the Switch Configuring sFlow 217 Figure 96 sFlow Configuration...
Page 218: ...CHAPTER 4 Configuring the Switch Configuring sFlow 218...
Page 286: ...CHAPTER 6 Performing Basic Diagnostics Running Cable Diagnostics 286...
Page 292: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 292...
Page 294: ...SECTION III Appendices 294...
Page 312: ...GLOSSARY 312...
Page 317: ......
Page 318: ...GEP 5070 E042013 ST R01...