6. (Trained service technician only) Make sure that the microprocessor 2 heat sink is installed
correctly and the thermal material is correctly applied.
7. (Trained service technician only) Replace microprocessor 2.
•
80070301-0303xxxx : Sensor [SensorElementName] has transitioned to non-recoverable from
a less severe state.
IMM has detected that the temperature for CPU 3 has transitioned to a non recoverable state.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0524
User Response
Complete the following steps:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Ensure system cover is latched properly.
4. Make sure that the room temperature is within operating specifications.
5. Make sure that the microprocessor 3 heat sink is securely installed.
6. (Trained service technician only) Make sure that the microprocessor 3 heat sink is installed
correctly and the thermal material is correctly applied.
7. (Trained service technician only) Replace microprocessor 3.
•
80070301-0304xxxx : Sensor [SensorElementName] has transitioned to non-recoverable from
a less severe state.
IMM has detected that the temperature for CPU 4 has transitioned to a non recoverable state.
Severity
Error
Serviceable
Yes
Automatically notify support
602
Lenovo System x3750 M4 Installation and Service Guide
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...