2. Make sure that the circuit breaker for the dc power supply is off.
3. Attach the dc power cable to the new power supply. Make sure that the power cable wires are
connected securely to the -48 V, ground, and to the -48 V return terminals (as shown in the following
illustration).
Power input LED
Power output LED
Power error LED
-48V
Ground
-48V return
4. Facing the rear of the server, insert the power supply spacer into the left side of the power-supply
bay (against the bay wall) against the wall on the left side of the power supply bay, if you removed
it.
Filler
panel
00
00
00
0000000
0000000
0000000
0000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
000000
000000
000000
000000
000000
00
00
00
Power supply
release tab
Spacer
Spacer
release tab
750-watt -48 volt dc
power supply
5. Slide the power supply spacer into the bay until it snaps into place on the tabs that are on the side
of the bay.
6. Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the power-supply
connector.
7. Route the power cord through the hook-and-loop strap so that it does not accidentally become
disconnected.
8. Turn on the circuit breaker(s) for the dc power supplies.
9. Reconnect any external cables that you disconnected.
10. Slide the server back into the rack, if it was in a rack.
11. Turn on the server and the peripheral devices.
12. Make sure that the server starts correctly and recognizes the newly installed device, and make sure that
no error LEDs are lit.
Removing the system board
Use this information to remove the system board.
Before you remove the system board from the server, take the following steps to save data, firmware,
and configuration data:
Removing and replacing components
299
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...