4000001e-00000000 : Running the backup Management Controller [arg1] main application.
The IMM was unable to run the primary IMM image and has resorted to running the backup image.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix:
IMM
ID:
0030
User Response
Update the IMM firmware.
Important:
Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
•
4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the
correct firmware. The Management Controller is unable to match its firmware to the server.
The server does not support the installed IMM firmware version.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix:
IMM
ID:
0031
User Response
Update the IMM firmware to a version that the server supports.
Important:
Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for the cluster solution before you update the code.
•
40000020-00000000 : Management Controller [arg1] Reset was caused by restoring default values.
The default configuration has been restored to the Integrated Management Module.
Appendix D. Integrated management module II (IMM2) error messages
523
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...