1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Inspect the processor sockets for foreign debris or damage. If debris is found, remove the
debris.
3. If the error re-occurs, or socket damage is found, replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 283
–
“Replacing a microprocessor and heat sink” on page 287
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.680B9 [S.680B9] External QPI Link Failure Detected. : External QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Inspect the processor sockets for foreign debris or damage. If debris is found, remove the
debris.
3. If the error re-occurs, or socket damage is found, replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 283
–
“Replacing a microprocessor and heat sink” on page 287
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
W.11004 [W.11004] A processor within the system has failed the BIST. : Processor Self Test Failure
Detected
Severity
Warning
User Response
Complete the following steps:
1. If the processor or firmware was just updated, check the IBM support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If there are multiple Processors, swap Processors to move affected processor to another
processor socket and retry. If problem follows the affected processor, or this is a single processor
system, replace the processor. Inspect the processor socket on each processor removal and
replace system board first if the processor socket is damaged or mis-aligned pins are found.
3.
Replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 283
498
Lenovo System x3750 M4 Installation and Service Guide
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...