Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2.
Update the UEFI image.
3.
Replace the system board.
Related links
–
“Updating the firmware” on page 131
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.3050007 [S.3050007] A firmware fault has been detected in the UEFI image. : Internal UEFI
Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2.
Update the UEFI image.
3.
Replace the system board.
Related links
–
“Updating the firmware” on page 131
–
“Removing the system board” on page 299
–
“Replacing the system board” on page 301
•
S.3058004 [S.3058004] A Three Strike boot failure has occurred. The system has booted with
default UEFI settings. : POST failure has occurred! System booted with default settings.
Severity
Error
User Response
Complete the following steps:
1. This event resets UEFI to the default settings for the next boot. If successful, the Setup Utility is
displayed. The original UEFI settings are still present.
2. If you did not intentionally trigger the reboots, check logs for probable cause.
3. Undo recent system changes (settings or devices added). If there were no recent system
changes, remove all options, and then remove the CMOS battery for 30 seconds to clear CMOS
contents. Verify that the system boots. Then, re-install the options one at a time to locate the
problem.
4. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
5.
Update the UEFI firmware.
6.
Replace the system board.
492
Lenovo System x3750 M4 Installation and Service Guide
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...