• Change the position of the power-on password switch (switch 6) on the system board switch block (SW7)
to bypass the power-on password check (see Table 3 “System-board SW7 switch block descriptions” on
page 31 for more information).
IMM lowsecurity
jumper (J86 )
UEFI boot
recovery
jumper (J71)
IMM recovery
jumper (J115 )
Sw7
switch block
1
2
3
4
5
6
7
8
OFF
3
2
1
ON
3
2
1
Attention:
Before you change any switch settings or move any jumpers, turn off the server; then,
disconnect all power cords and external cables. Read “Safety” on page v, this information will help you
work safely. Do not change settings or move jumpers on any system-board switch or jumper blocks
that are not shown in this document.
The default for all of the switches on switch block SW7 is Off.
While the server is turned off, move switch 6 on switch block SW7 to the On position to enable the
power-on password override. You can then start the Setup utility and reset the power-on password. You
do not have to return the switch to the previous position.
The power-on password override switch does not affect the administrator password.
Administrator password
This section explains the administrator password.
If an administrator password is set, you must type the administrator password for access to the full Setup
utility menu. You can use any combination of 6 to 20 printable ASCII characters for the password.
Attention:
If you set an administrator password and then forget it, there is no way to change, override,
or remove it. You must replace the system board.
Using the Boot Manager
This section explains how to use the Boot Manager.
Configuration information and instructions
143
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...