10. Make sure that the ac power LED and the dc power LED on the power supply are lit, indicating that
power is being supplied to the power supply through the power cord. During normal operation, both ac
and dc power LEDs are lit. For other combinations of LEDs, see “Power-supply LEDs” on page 170.
Removing a hot-swap fan assembly
Use this information to remove a hot-swap fan assembly.
Attention:
To ensure proper server operation, replace a failed hot-swap fan within 30 seconds.
To remove a hot-swap-fan, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
If the server is in a rack, slide the server out of the rack.
Step 3.
Remove the top cover (see “Removing the server top cover” on page 216).
Step 4.
Pull the fan latch to the left to release the fan from the fan connector and pull the fan out of the
fan cage assembly.
0000000
0000000
0000000
0000000
0000000
0000000
000000
000000
000000
000000
000000
000000
000000
000000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
Hot-swap
fan error LED
Hot-swap fan
Fan latch
Attention:
To ensure proper operation, replace a failed hot-swap fan within 30 seconds.
Step 5.
If you are instructed to return the fan, follow all of the packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing a hot-swap fan assembly
Use this information to replace a hot-swap fan assembly.
The server comes standard with six speed-controlled hot-swap cooling fans.
Attention:
To ensure proper operation, replace a failed hot-swap fan within 30 seconds.
To install or replace a hot-swap fan, complete the following steps:
Removing and replacing components
251
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...