GENERAL RULES FOR INSTALLATION
Maximum distance between EP or
handset and power supply.
In the riser, the quantity of devices
managed by a power supply are
shown in table 4, table 5, and table 6.
Notes:
1. The current can also be affected by the distance.
Here every floor is supposed to be 5 m height.
2. If there are many 323002, it is supposed that the
distance of 323002is 0.5 m.
Case 1, case 2, case 3, case 4, case 7,
case 8, case 9 are for 323005(PW1)
and 323010(aPW1). Case 4, case 5,
case 6, case 10, case 11, case 12 are
for 323005(PW1).
How many apartments
on every floor
HANDSET
Case 1
Case 2
Case 3
Case 4
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
2 apartments/floor
(Don’t use extra power cable)
24
max: 12 floors
4
max: 2 floors
16
max: 8 floors
10 [*1]
max: 5 floors
2 apartments/floor
(use extra power cable)
78
max: 39 floors
-
-
16
max: 8 floors
20 [*1]
max: 10 floors
4 apartments/floor
40
max: 10 floors
4
max: 1 floor
16
max: 4 floors
12 [*1]
max: 3 floors
8 apartments/floor
56
max: 7 floors
4
max: 1 floor
16
max: 2 floors
12 [*1]
max: 2 floors
12 apartments/floor
56
max: 5 floors
4
max: 1 floor
16
max: 2 floors
12 [*1]
max: 1 floor
16 apartments/floor
56
max: 4 floors
4
max: 1 floor
16
max: 1 floor
16 [*1]
max: 1 floor
20 apartments/floor
68
max: 4 floors
4
max: 1 floor
16
max: 1 floor
20 [*1]
max: 1 floor
24 apartments/floor
68
max: 3 floors
4
max: 1 floor
16
max: 1 floor
20 [*1]
max: 1 floor
28 apartments/floor
68
max: 3 floors
4
max:1 floor
16
max: 1 floor
20 [*1]
max: 1 floor
32 apartments/floor
68
max: 3 floors
4
max:1 floor
16
max: 1 floor
20 [*1]
max: 1 floor
36 apartments/floor
68
max: 2 floors
4
max:1 floor
16
max: 1 floor
20 [*1]
max: 1 floor
Table 4: case 1 to case 4, the quantity of devices managed by 323005 (PW1).
Table 5: case 1 to case 4, the quantity of devices managed by 323005 (Power supply).
How many apartments
on every floor
handSet
Case 5
Case 6
Case 7
Case 8
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
2 apartments/floor
(Don’t use extra power cable)
4 [*2]
max:2 floor
8 [*2]
max:4 floor
36
max: 18 floors
8
max: 4 floors
2 apartments/floor
(use extra power cable)
8 [*2]
max: 4 floors
90
max: 45 floors
8
max: 4 floors
4 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
56
max: 14 floors
8
max: 2 floors
8 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
72
max: 9 floors
8
max: 1 floor
12 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
76
max: 7 floors
8
max: 1 floor
16 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 5 floors
8
max: 1 floor
20 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 4 floors
8
max: 1 floor
24 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 4 floors
8
max: 1 floor
28 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 3 floors
8
max: 1 floor
32 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 3 floors
8
max: 1 floor
36 apartments/floor
4 [*2]
max: 1 floor
8 [*2]
max: 1 floor
80
max: 3 floors
8
max: 1 floor
Power supply check and calculation
64
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...