LEGRAND D45 SYSTEM Installation Manual Download Page 191

187

322050

1
2
3
4
5
6
7
8
9

10

*

#

260

175

33,5

23

1
2
3
4
5
6
7
8
9

10

*

#

14

10

1
2
3
4
6

5
7

8
9

12 11

13

15

16

D45 System

Description

Colour 7” handsfree indoor handset

D45 System indoor handsfree video handset with 7” analogue LCD LED backlit display. 
Complete door entry functions with alarms management. International standard SOS 
pushbutton and keyboard for intercom function and programming device. Direct call to 
switchboard function. 12 ring tones selectable for different call types. Surge protection. 
Wall mount installation. 

Technical data

LCD display resolution: 

480 x 234

Power supply : 

30 Vdc

Stand by absorption:  

≤ 20 mA @ 30 V

Max. operating absorption: ≤ 145 mA @ 30 V
Operating temperature:   (-10)-(+40)°C

Dimensional data

Legend

1. 

Loudspeaker

2. 

SOS key

3. 

Monitor key

4. 

Information LED

5. 

Switchboard call key

6. 

Communication LED

7. 

Answer key

8. 

Unlock key

9. 

Shortcut key

10. 

Color control knob

11. 

Brightness knob

12. 

Ring volume control knob

13. 

Microphone

14. 

Numerical keys and corresponding numbers

15. 

Defense area LED 1 to 8

16. 

LCD Display

Front view

Dimensions in mm

 

BT00472-b-en    

03/06/2013

Summary of Contents for D45 SYSTEM

Page 1: ...the global specialist in door ENTRY SYSTEM D45 SYSTEM THE HIGH PERFORMANCE AUDIO VIDEO DOORENTRY SYSTEM Project and installation technical guide...

Page 2: ......

Page 3: ...technicalguide GENERAL RULES FOR INSTALLATION GENERAL FEATURES WIRING DIAGRAMS AND VARIANTS CATALOGUE TECHNICAL SHEETS...

Page 4: ......

Page 5: ...configuration examples 45 Accessory configuration examples 47 Lock type and distance limits 55 Power supply installation rules 57 Power supply check and calculation 62 Maximum system limits 67 Troubl...

Page 6: ...on Diagram 7 102 Addictional power supply connection Diagram 8 103 Entrance pannel auxiliary power supply connection Diagram 9 103 Power supply connection for switchboard Diagram 10 104 Connection of...

Page 7: ...141 BT 321071 111 146 BT 322052 111 BT 321061 111 BT 322050 111 187 BT 321011 111 129 BT 321060 111 136 BT 322040 111 183 BT 323001 111 194 BT 323002 112 197 BT 323022 112 240 BT 323003 112 198 BT 32...

Page 8: ......

Page 9: ...GENERAL FEATURES...

Page 10: ...and services World presence Technical assistance World presence web sites in order to find your nearest subsidiaries For after sales technical assistance please refer to the www bticino com www legra...

Page 11: ...d the check of the absorptions You can make in a few moments intercom systems video entry system and integrated communication solution using the product that best suits your needs The design of the sy...

Page 12: ...gramming of D45 devices The software is supplied within a configuration tool 323020 This package consists of the Tool interface and the Configuration tool used by technicians to download the configura...

Page 13: ...unication between two internal units MASTER It is the video internal unit that turns on when a call is received SLAVE It is the video internal unit connected in parallel to the master video internal u...

Page 14: ...VE SECURITY FUNCTIONS Alarm fuction integreted on the internal unit SOS pushbutton on all the indoor devices The use of UTP cables and RJ45 connections for all the devices provides quick and easy inst...

Page 15: ...floor2 Floor 1 Riser 1 Apartment2 Apartment4 Apartment3 6 6 6 6 5 1 2 Apartment1 Tofloorshunt floor2 Floor 1 Riser 2 Apartment2 Apartment4 Apartment3 6 6 6 6 5 1 Torisershunt Riser3 4 4 2 7 GUIDE D45...

Page 16: ...010 322011 322030 322031 322020 322021 Colour video Finishes colours Zamak Zamak Zamak Aluminium Plastic Wall mounted installation Flush mounted installation Pushbutton call Digital call Door lock rel...

Page 17: ...our hands gree 7 Colour hands free 3 5 COLOUR HANDS FREE 4 3 321070 321071 322050 321011 322052 321060 321061 Colour video Handsfree Finishes colours White finish metal cover White White White White W...

Page 18: ...o the BUS through 323002 One 323002 can be connected to 4 handsets The device converts the BUS video signals to transfer mode and then distributes them to the connected handsets 323002 POWER SUPPLY Sy...

Page 19: ...handsets and calling and monitoring Small EP D45 IP INTERFACE This interface permit to expand the distances limits of the backbone and it could be usefull in application with big distances between en...

Page 20: ...ons panel 322033 Embedded 325 x 125 x 44 5 30V 5 mA 30V 28 mA Floor shunt 323002 DIN Rail 72 x 105 x 33 30V 25 mA 30V 130 mA Riser shunt 323003 DIN Rail 106 x 105 x 33 30V 60 mA 30V 110 mA Entrance pa...

Page 21: ...al dwellings on the same floor and to multifamily systems where maximum distance between entrance panel and internal units is required The floor shunt provides star connection of up to 4 apartments En...

Page 22: ...ntrancepanel Floorshunt323002 Powersupply323005 Riser 1 Branch 1 floor 1 For the installation of video systems with several branches the 2 way video SINGLE BUILDING WITH MORE RISERS 2 WayVideo Splitte...

Page 23: ...Branch 2 floor 2 Apartment1 Apartment2 Apartment4 Apartment3 Tofloor shunt323003 ConnectionswithRJ45 Cat5E 6cable Riser2 Floorshunt323002 15 GUIDE D45 System WWW LEGRAND COM...

Page 24: ...RE SECONDARY ENTRANCE PANELS System composition Mainentrancepanel Tonext risershunt COMMON SYSTEM SECTION Powersupply323005 Powersupply323005 Powersupply323005 Powersupply323005 Risershunt323003 Riser...

Page 25: ...5 Cat5E 6cable RiserXX Riser2 Riser1 BUILDING 1 Riser entrancepanel BUILDING XX BUILDING 2 Riser entrancepanel Riser entrancepanel Floorshunt323002 Floorshunt323002 Floorshunt323002 17 GUIDE D45 Syste...

Page 26: ...ARD System composition COMMON SYSTEM SECTION Mainentrancepanel Powersupply323005 Powersupply323005 Tonext risershunt Powersupply323005 Powersupply323005 Switchboard323001 EP Switchboard shunt323018 Po...

Page 27: ...5 Cat5E 6cable RiserXX Riser2 Riser1 BUILDING 1 Riser entrancepanel BUILDING XX BUILDING 2 Riser entrancepanel Riser entrancepanel Floorshunt323002 Floorshunt323002 Floorshunt323002 19 GUIDE D45 Syste...

Page 28: ...thRJ45 Cat5E 6cable Mainentrance panel Risershunt323003 EP Switchboardshunt 323018 Switchboard323001 Powersupply323005 Riserentrance panel Powersupply323005 Tonextrisershunt 323003 Tonextfloorshunt323...

Page 29: ...Tonextfloorshunt323002 SmallEP322020 SmallEP322020 Touchscreenvideointernalunit Touchscreenvideointernalunit Powersupply323010 Powersupply323010 Floorshunt323002 Floorshunt323002 21 GUIDE D45 System...

Page 30: ...ocedure D45 system devices may be configured in two ways physical configuration has priority over the software configuration configuration with SF2 software Configuration with SF2 software The system...

Page 31: ...t involved in the conversation are temporarily excluded in order to guarantee the privacy of video door entry conversations When calling from an entrance panel that is temporarily excluded a time out...

Page 32: ...self switching on pushbutton will scroll through the various entrance panels and the cameras connected to the system MASTER SLAVE FUNCTION The system offers the MASTER SLAVE function when the call is...

Page 33: ...ng an unanswered call The video door entry system message can be recorded in 2 ways STILLS the message includes a picture of the visitor and the recorded audio message 160 messages max VIDEOS the mess...

Page 34: ...s The sensors are connected directly to the internal unit When an alarm situation occurs if the alarm is not cancelled within the set time default 40 seconds the message alarm is sent to the switchboa...

Page 35: ...ards connected max 16 LIFT CONTROL Call the lift at the own floor by the internal unit before to go out Avoiding to stand up in front of the elevator many times in the morning Send the lift to the lob...

Page 36: ......

Page 37: ...GENERAL RULES FOR INSTALLATION...

Page 38: ...applications it is necessary that the layout of the house and a general furniture plan are made available to the installer It is also important to check the accuracy of the details of the estimate in...

Page 39: ...standard NFC 32062 flame retardant conforming to standards IEC 332 1 and NFC 32070 2 1 5 2 mm Colour RAL 7035 light grey Bticino CAT NO 4 pair or 2 x 4 pair 24 AWG UTP 100 ohms PVC or LSZH CAT 5e ECVE...

Page 40: ...our U UTP Sheath Length Packaging 032750 LSZH 305 m box 032751 PVC 305 m box 032873 LSZH 1000 m reel 032874 PVC 1000 m reel CAT 6 U UTP CABLES 032754 Category 6 U UTP unshielded cable with 24AWG 0 51...

Page 41: ...Table 1 Two standards T568A and T568B of wires connection both suitable although it is recommended that they are not mixed in the same installation Table 1 shows the two standards 87654321 12345678 Pa...

Page 42: ...ip the cable sheath off Step 3 separate the exposed coloured strands Smooth out the strands and untwist each pair Straighten out each wire and put them in order of colour Make sure the cable is free o...

Page 43: ...lick sound should be heard The following picture shows a correctly fitted connector Step 8 test the cable Connect the two RJ45 connectors to the tester Turn on the test The two groups of lights will b...

Page 44: ...cm RECOMMENDATION FOR THE INSTALLATION POSITION OF THE SMALL EP EP MAIN EP The most important condition to observe in the positioning of cameras is that they must not be turned towards light source f...

Page 45: ...method Don tinstallinhotordampplaces Sizeoverview Note theflushmountedboxmustbeorderedseparately InstalltheEPonthedoor InstalltheEPonthewall 1 4 1 4 Flushmountedbox Rack Screw Flushmountedbox Rack Scr...

Page 46: ...amps and fit the cover to the body using the two grooves on the top 3 secure the cover in position 4 tighten up the bottom screw Installation instructions 1 Fix the base to the flush mounted box using...

Page 47: ...the two in the same digit The DDDD address can also be replaced by meaningful words flowers etc in this case the visitor user of the Switchboard must find the right name in the directory Only possibl...

Page 48: ...ypical of the installation max value 99 The simplified configuration can be applied to a standard installation or to a district of a multichannel installation inheriting the limits of the chosen confi...

Page 49: ...number of units riser for each district 400 Total number of apt villas for each riser 800 if only 1 handset in each apt Total number of apt villas for each riser 400 if only 2 handsets in each apt Tot...

Page 50: ...software then download to the devices using the RS232 port Remarks forthe3aboveconfigurationmodes theparameters toconfigurearethesame thereforeitisnot necessarytodescribetheconfigurationprocedures se...

Page 51: ...tion Mode 1 is used The Switchboard directly connected to the main EP is no 2 main EP configuration should be as follows C2ThispositioncanusetheEPkeyboardortheconfigurationtoolfortheconfiguration Posi...

Page 52: ...2 is used the Switchboard directly connected to the main EP is no 2 MC Main EP configuration should be as follows NOTE thereisanadditionalconfigurationslot M M switchboardaddressnumber canbesetonlybyk...

Page 53: ...ical number of handsets per floor POSITION Mode 1 Mode 2 F FF FF F I II II I I Default for II is 04 need not connect the configurator II II setup using same value for all system handsets I Example A T...

Page 54: ...dsets is 1206 each floor has 8 handsets System configuration Mode 2 is used The handset configuration should be as follows Position value RemarkS F 1 F 2 I 0 It is ok not to insert configurator 0 I 6...

Page 55: ...ged by this riser shunt Max handset the highest handset address managed by this riser shunt Configuration bit Definition Remark CF11 CF12 First EP number in this riser From 1 to 80 CF13 CF14 Riser EP...

Page 56: ...config needed CF4 N 5 CF5 F FF is 20 default No need for configuration CF6 F CF7 I II is 4 default No need for configuration CF8 I C C 2 M M 0 0 no config needed Example B The number of riser shunts i...

Page 57: ...number where this power management starts from FF Max the floor number where this power management ends FF Max must over or equal to FF Min II number of apartments on each floor at Mode 1 the default...

Page 58: ...s used as auxiliary power supply and that the smart power supply function is kept on When type 0 no Typ power supply management function smart power function 0 1 2 ASR ALARM SINKING RESERVE OF EACH AP...

Page 59: ...on the power supply address is 12 the max current of the alarm sensor is 300 mA System configuration Mode 1 is used The power supply configuration should be as follows Position Mode 1 Value for config...

Page 60: ...nction and the power management function the power supply address is 12 max current of the alarm sensor is 300 mA System configuration Mode 2 is used The power supply configuration should be as follow...

Page 61: ...not need to be set the range of handset addresses managed by the power supply is 125 163 Without alarm it means that the current of alarm sensor is 0 mA The system used Mode 3 configuration The power...

Page 62: ...oSmallEP sometimesifseveral SmallEPcallhandsetsatthesametime apower supplyoverloadmayoccur Underthissituation thereisariskofdamagetothepowersupply Suggested power supply solution and related configura...

Page 63: ...CTOR The actual working environment may be damp or hot which can cause inferior RJ45 connectors to rust Lock type and distance limits We recommend that Legrand Ortronics connectors are used see specif...

Page 64: ...ply in the above drawing is the system riser power supply It can be shared by the riser shunt without the need for an auxiliary Power supply The power supply is the auxiliary EP power supply in some c...

Page 65: ...r impedance matching for the audio channel at the same time Therefore In the project usually PWS smart power supply is used as system power only when the system needs auxiliary power supply with smart...

Page 66: ...323005 323003 EP 323005 323005 Unit 2 Unit 1 Unit 3 GENERAL RULES FOR INSTALLATION During installation of the system two power supply solutions can be chosen according to different situations One3230...

Page 67: ...is assistant power supply impedance switch of Power supply must be OFF alarm Small EP CF1 CF3 NNN CF4 CF11 CF12 Type CF13 ASR CF14 M CF15 LE CF1 CF3 NNN CF4 CF11 CF12 Type CF13 ASR CF14 M CF15 LE 1 no...

Page 68: ...nt in the system the system power supply should be connected and set as following drawing Impedance switch ON OFF Powersupply 323005 4 When there is no 323013 on the system BUS the system power supply...

Page 69: ...the impedance setting switch of 323005 must be switched to off as per the following drawing 1 the connection of the auxiliary power supply inside the riser 2 When there is a Switchboard in the system...

Page 70: ...t alarm sensor The maximum quantity of handsets and EP that the riser system power supply can accept TYPE OF HANDSETS 1 2 3 4 5 6 7 8 9 10 11 12 1 EP Riser shunt without A C 40 4 12 4 1 N 4 2 52 4 12...

Page 71: ...1 small EP and 1 EP can work at the same time with handsets connected to the same power supply 5 When using an entrance panel video mixer in the riser more than one EP in the riser the distance betwee...

Page 72: ...x 1 floor 28 apartments floor 68 max 3 floors 4 max 1 floor 16 max 1 floor 20 1 max 1 floor 32 apartments floor 68 max 3 floors 4 max 1 floor 16 max 1 floor 20 1 max 1 floor 36 apartments floor 68 max...

Page 73: ...6 max 1 floor 36 3 max 2 floors 4 3 max 1 floor 12 1 max 1 floor 32 apartments floor 16 max 1 floor 36 3 max 2 floors 4 3 max 1 floor 12 1 max 1 floor 36 apartment floor 16 max 1 floor 36 3 max 1 floo...

Page 74: ...ets floor 4 2 3 6 4 5 8 handsets floor 4 2 3 6 4 5 12 handsets floor 4 2 3 6 4 5 16 handsets floor 4 2 3 6 4 5 20 handsets floor 4 2 3 6 4 5 24 handsets floor 4 2 3 6 4 5 28 handsets floor 4 2 3 6 4 5...

Page 75: ...ork system 100 each IP area expandable District generator in the whole system non IP network system 5 Using level connection with 5 District generators it can expand 16 networking branch routes Switch...

Page 76: ...amplifier video splitter etc in transmission channel the video signal will have distortion and the quality of the image will decrease In D45 the maximum level of cascade is 6 If any of the following d...

Page 77: ...loor shunt 50 m Max distance line C Power supply Entrance panel 70 m LINE A Furthest internalunit Additionalpowersupplyof floorshunt323010 LINE C Entrance panel LINE B Floorshunt 323002 Powersupply 32...

Page 78: ...main Power supply 50 m Max distance line C Internal unit Floor shunt 50 m Max distance line D Entrance panel Power supply 70 m ON SD 1 2 3 4 ON SD 1 2 3 4 LINE A Furthest internalunit Floorshunt 32300...

Page 79: ...r supply of Flor shunt 50 m Max distance line C Entrance panel Power supply 70 m ON SD 1 2 3 4 ON SD 1 2 3 4 LINE B LINE A LINE C Mainpowersupply 323005 Floorshunt 323002 Risershunt 323003 Additionalp...

Page 80: ...in number the handset answers but there is no voice or video signal If the entrance panel can call all handsets with a number smaller than a certain number e g all handset with number lower than 501 c...

Page 81: ...n Apartment interface the household number cannot be set When the last two digits of the household number are higher than the number of users II on each floor the household number cannot be set For ex...

Page 82: ......

Page 83: ...WIRING DIAGRAMS...

Page 84: ...F F I I I I 1 2 BUS BUS BUS BUS 321070 321070 321070 321070 321070 321070 321070 321070 323002 323002 323005 322011 0 2 0 1 0 2 0 4 0 2 0 2 0 2 0 3 0 1 0 1 0 1 0 4 0 1 0 2 0 1 0 3 L 12 L UNLOCK PB L1...

Page 85: ...CHtoON D AuxialiaryPWSmustbeusedinrelationwiththesystem distanceextension seespecificsection Configureandinsertthejumperswiththesystem SWITCHEDOFF Alsoeverytimetheconfigurationis modifiedthepwsmustbes...

Page 86: ...005 322011 F F I I I I F F I I I I F F I I I I F F I I I I 1 2 BUS BUS BUS BUS 321070 321070 321070 321070 323002 0 1 0 2 0 8 0 8 0 1 0 3 0 1 0 1 0 8 0 8 0 1 0 4 L 12 L UNLOCK PB L1 1 2 3 4 1 2 3 4 32...

Page 87: ...hedOFFandONagain waitingabout1minute WARNINGS ITEM DescriPTION 322011 Digital call entrance panel 323005 Main power supply 323007 Two branches video splitter 323002 Floor shunt 321070 7 Touch screen i...

Page 88: ...esystem distanceextension seespecificsection NOTE seeconnectionvariants Configureandinsertthejumperswiththesystem SWITCHEDOFF Alsoeverytimetheconfigurationis modifiedthepwsmustbeswitchedOFFandONagain...

Page 89: ...BUS 321070 321070 321070 321070 B D C A 323005 323002 x x 0 1 x x 0 4 x x 0 2 x x 0 3 ON SD 1 2 3 4 ON SD 1 2 3 4 B D C A 323005 323003 323003 CF4 2 CF4 3 A A A A FLOOR XX D Tonextfloor shunt323002 To...

Page 90: ...oON D AuxialiaryPWSmustbeusedinrelationwiththesystem distanceextension seespecificsection NOTE seeconnectionvariants Configureandinsertthejumperswiththesystem SWITCHEDOFF Alsoeverytimetheconfiguration...

Page 91: ...321070 321070 321070 321070 B D C A 323005 323002 x x 0 1 x x 0 4 x x 0 2 x x 0 3 ON SD 1 2 3 4 ON SD 1 2 3 4 B D C A 323005 323003 323003 CF4 2 C 1 CF4 3 C 1 A A A A FLOOR XX Tonextfloor shunt323002...

Page 92: ...ON SD 1 2 3 4 B D C A 323005 323003 323001 MC Min MC Min MC Max MC Max EPS EPS P S 0 1 0 1 0 1 0 323013 D C B Diagram 5 RISER BLOCK 1 RISER BLOCK 2 Entrance panel Floor shunt 323002 Entrance panel Fl...

Page 93: ...tem distanceextension seespecificsection Configureandinsertthejumperswiththesystem SWITCHEDOFF Alsoeverytimetheconfigurationis modifiedthepwsmustbeswitchedOFFandONagain waitingabout1minute WARNINGS IT...

Page 94: ...4 C F 5 C F 6 C F 7 M 323017 OUT OUTPUT8 OUTPUT7 OUTPUT6 OUTPUT5 OUTPUT4 OUTPUT3 OUTPUT2 OUTPUT1 CF1 CF2 CF3 CF4 CF5 CF6 CF7 0 4 0 9 6 0 1 M 1 323017 B B D D Diagram 6 Riser with lift control interfa...

Page 95: ...T5 OUTPUT4 OUTPUT3 OUTPUT2 OUTPUT1 CF1 CF2 CF3 CF4 CF5 CF6 CF7 0 4 0 2 7 1 1 M 1 323017 LIFT CTRL 1 FLOOR 1 FLOOR 2 UPkeyofliftin1groudfloor Downkeyofliftin8floor Downkeyofliftin3floor Downkeyofliftin...

Page 96: ...rswiththesystem SWITCHEDOFF Alsoeverytimetheconfigurationis modifiedthepwsmustbeswitchedOFFandONagain waitingabout1minute WARNINGS ITEM DescriPTION 322011 Digital call entrance panel 322020 mall entra...

Page 97: ...I 1 2 BUS 321070 323002 B D C A 323010 R1 R2 R3 R4 R1 R2 R3 R4 F F I I I I 1 2 BUS 321070 323002 B D C A 323010 R1 R2 R3 R4 R1 R2 R3 R4 322020 322020 Villa 2 Villa 1 A D A D 89 GUIDE D45 System WWW LE...

Page 98: ...urationoradvancedconfigurationby softwareMHSUITE Configureandinsertthejumperswiththesystem SWITCHEDOFF Alsoeverytimetheconfigurationis modifiedthepwsmustbeswitchedOFFandONagain waitingabout1minute WAR...

Page 99: ...F I I I I F F I I I I F F I I I I F F I I I I 1 2 BUS BUS BUS BUS 321070 321070 321070 321070 321070 321070 321070 321070 323002 323002 x x 0 1 x x 0 4 x x 0 2 x x 0 3 0 1 0 1 0 1 0 4 0 1 0 2 0 1 0 3...

Page 100: ...edthepwsmustbeswitchedOFFandONagain waitingabout1minute WARNINGS System with D45 interface and software switchboard D C B B D C A BUS 323005 322011 L 12 L UNLOCK PB L1 LAN SYSTEM1 SYSTEM2 WEP DC V OUT...

Page 101: ...EM2 WEP DC V OUT GAIN Speed Full Link Aux System 323011 323011 B D C A BUS 323005 322011 L 12 L UNLOCK PB L1 LAN SYSTEM1 SYSTEM2 WEP DC V OUT GAIN Speed Full Link Aux System 323011 323011 B D C A 3230...

Page 102: ......

Page 103: ...WIRING DIAGRAMS VARIANTS...

Page 104: ...ND 12V F1 SENSOR GND 12V F8 ALARMSENSORS 323015 SmallEP Handset Normallyastandard0 5mm2 cablecanbeused dependingonsensortypeandinstallationdistance Forvideosignalsastandardcablecanbeused Fordatasignal...

Page 105: ...sensor 6 sensor 5 gas sensor smoke sensor door sensor infrared sensor 10 K 10 K NO C NC 12 V GND 12 V F1 GND F8 F7 F6 F5 F4 F3 F2 10 K 10 K Fn GND NC C 10 K 10 K Fn GND NC C NC C 10 K 10 K Fn GND NO...

Page 106: ...2 POWER ToIU4 SubSystemOUT POWER Sub System IN To IU 2 Remarks when the total power consumption for all handsets connected to 323008 exceeds the limit an auxiliary power supply 323010 is required Dia...

Page 107: ...2 POWER SubSystemIN To IU2 To IU3 To Handset SubSystemOUT 346858 INT EXT 230Vac PRI SCS A V SCS BUS BUS BUSSCS D45 SYSTEM BTICINO 2 WIRE SYSTEM 344602 344602 346030 346858 323002 Diagram 3 N 1 N 2 FF...

Page 108: ...or unit can be set as the master indoor unit 1 2 POWER ToHANDSET4 Systeminput connectto323002 output Systemoutput connectto323002 input ToHANDSET2 ToHANDSET3 POWER 322020 323015 323009 Handset notconf...

Page 109: ...an be replaced with 323004 to obtain up to 25 entrance panels B D C A ON SD 1 2 3 4 ON SD 1 2 3 4 1 2 3 4 POWER ToRisershuntorPowersupply 323005 323003 EntrancePanel EntrancePanel EntrancePanel Entran...

Page 110: ...size1mm2 andmaxdistance2meters 8A cos 1 24Vac 24Vdc 4A cos 0 7 24Vac 3A cos 0 4 24Vac B D C A N L L E N Blue N Yellow and green Brown L AC input This wire must be connected to earth ground 1 2 RiserOU...

Page 111: ...d to earth ground N L Brown L AC input This wire must be connected to earth ground RiserOUT BACKBONE RiserIN 322011 323010 Diagram 8 Power supply connection for switchboard A A Advancedconfigurationby...

Page 112: ...3010 B D C A 24Vdc BATTERY B D C A 12Vdc BATTERY 12Vdc BATTERY Back up battery connection Diagram 12 Floor call connection Diagram 11 B D C A 24Vdc BATTERY Enabletheservicewiththecode 686868 16 1 LONG...

Page 113: ...IN OUT connection Diagram 13 B D C A F F I I I I BUS x x x x F F I I I I BUS 0 1 0 1 L 12 L UNLOCK PB L1 Riser 321070 321070 323022 323022 322030 323005 105 GUIDE WWW LEGRAND COM...

Page 114: ...RJ45 Cat5E 6cable 4Wires 2Wires F F I I I I 0 1 0 1 1 2 3 4 B D C A 321070 323023 323010 CF1 OFF CF2 OFF CF3 OFF CF4 ON 322020 322020 323015 323015 Single family system with more then 1 entry panel 10...

Page 115: ...I I I F F I I I I F F I I I I BUS BUS BUS BUS F F I I I I 0 1 0 1 323010 322020 323015 322020 323015 322020 323015 CF1 OFF CF2 OFF CF3 ON CF4 OFF 321070 321070 321070 321070 323023 323009 Single famil...

Page 116: ......

Page 117: ...CATALOGUE...

Page 118: ...single call small street panel to be installed in one family systems or as private street panel in multifamily systems Touch sensitive pushbutton for calling indoor handsets and direct conversation Do...

Page 119: ...een Pack Cat Nos Hands free colour internal units 1 BT 321060 For standard video door entry functions plus direct call Hands free colour internal unit with 3 5 TFT LED backlit screen Equipped for stan...

Page 120: ...o signal can only be transferred from input to output Provides compensation to the two channels separately and adapts the video signal output from the street panel for different distances via settings...

Page 121: ...s max per accessory Compatible with coaxial camera 12V Pack Cat Nos System accessories continued Lift control interface 1 BT 323017 For integrating the D45 system with the elevator system Possibility...

Page 122: ......

Page 123: ...TECHNICAL SHEETS...

Page 124: ...ich can be selected by item code For each device the technical sheet shows the following information Product description Related items Technical and dimensional data Configuration Collection diagram i...

Page 125: ...15 SOS alarm connector 16 SEP entrance panel connector 17 Alarm sensor connector 18 Unlock device connector 19 RJ45 System BUS connector 20 Anti removal switch 21 Loudspeaker Front side views Rear vie...

Page 126: ...ount installation Technical data LCD display resolution 320 x 234 pixels Power supply 30Vdc Stand by absorption 10 mA 30V Max operating absorption 140 mA 30V Operating temperature 10 40 C Dimensional...

Page 127: ...onfiguration MODE 2 The main characteristics for each configuration mode are listed below When the biggest number of FF in whole system is 20 and the biggest number of II is 4 and the total risers num...

Page 128: ...sage light will indicate status of this setting item 1 enable handset can monitor Small EP message light on 1 long tone Default cannot monitor Small EP This function is available only when the functio...

Page 129: ...ng forTime delay after alarm happens 25 The light of defence area give the parameter For example if the parameter is 3 then LED 3 will on 1 delay 40 s 1 long tone only LED 1 will on Default 40 s only...

Page 130: ...System configuration mode 2 is used The handset configuration should be as follows FF Floor number II Apartment number II Maximum apartments quantity per floor in a riser Position configuration value...

Page 131: ...NO C NO C 10 K 10 K Fn GND NO C sensor 8 sensor 7 sensor 6 sensor 5 gas sensor smoke sensor door sensor infrared sensor 10 K 10 K NO C NC 12 V GND 12 V F1 GND F8 F7 F6 F5 F4 F3 F2 10 K 10 K Fn GND NC...

Page 132: ...F4 SENSOR 4 GAS SENSOR F5 SENSOR 5 Theft alarm Infrared or non infrared Default is infrared sensor User can set it to be non infrared Can use short key to sensor active or idle F6 SENSOR 6 Infrared or...

Page 133: ...all mount installation Technical data Power supply 30Vdc Stand by absorption 20 mA 30V Max operating absorption 85 mA 30V Operating temperature 10 40 C LCD display resolution 320 x 240 Dimensional dat...

Page 134: ...nd configuration MODE 2 The main characteristics for each configuration mode are listed below When the biggest number of FF in whole system is 20 and the biggest number of II is 4 and the total risers...

Page 135: ...7 message light will indicate status of this setting item 1 enable handset can monitor Small EP message light on 1 long tone Default cannot monitor Small EP This function is available only when the fu...

Page 136: ...ens 25 The light of defence area give the parameter For example if the parameter is 3 then LED 3 will on 1 delay 40 s 1 long tone only LED 1 will on Default 40 s only for thief area alarm 2 delay 100...

Page 137: ...figuration should be as follows FF Floor number II Apartment number II Maximum apartments quantity per floor in a riser Position configuration value RemarkS F 1 F 2 I 0 It is ok not to insert configur...

Page 138: ...C NO C 10 K 10 K Fn GND NO C sensor 8 sensor 7 sensor 6 sensor 5 gas sensor smoke sensor door sensor infrared sensor 10 K 10 K NO C NC 12 V GND 12 V F1 GND F8 F7 F6 F5 F4 F3 F2 10 K 10 K Fn GND NC C 1...

Page 139: ...heft alarm Infrared or non infrared Default is infrared sensor User can set it to be non infrared Can use short key to sensor active or idle F6 SENSOR 6 Infrared or non infrared Default is non infrare...

Page 140: ...mount installation Technical data Power supply 30Vdc Stand by absorption 15 mA 30V Max operating absorption 85 mA 30V Operating temperature 10 40 C LCD display resolution 320 x 240 Dimensional data Le...

Page 141: ...cteristics for each configuration mode are listed below When the biggest number of FF in whole system is 20 and the biggest number of II is 4 and the total risers number is 50 we recommend to choose M...

Page 142: ...can be heard as a prompt You can save it If not correct three short tones will be heard and no need to save it Exit 1 Short press on the Door lock key and move to the last digit Then short press on th...

Page 143: ...ance panel and the message LED will be ON With the parameter being 0 the indoor unit can t monitor the entrance panel and the message LED will be OFF In the setting process the parameter will be autom...

Page 144: ...ould be as follows Example B The number of handsets is 1206 each floor has 8 handsets System configuration MODE 2 is used The handset configuration should be as follows Position configuration value Re...

Page 145: ...wer supply 18 30Vdc Stand by absorption 100 mA 30V Max operating absorption 200 mA 30V Operating temperature 10 40 C LCD display size 7 LCD display resolution 800 x 480 Supported SD CARD 32 Gb maximum...

Page 146: ...ration MODE 1 and configuration MODE 2 The main characteristics for each configuration mode are listed below POSITION Mode 1 Mode 2 F FF FF F I II II I I Default for II is 04 need not connect the conf...

Page 147: ...nition of area 5 to area 8 Area1 to area 4 can t be changed Status display the detector status when it becomes blue detector is enabled and when it becomes gray means disabled Areas show area1 to area...

Page 148: ...ot to insert configurator 0 I 6 I 0 It is ok not to insert configurator 0 I 8 Configuration setting by inserting phisical configurators WAY 2 Side pushbutton functions SOS Key in case of urgent or une...

Page 149: ...music and photos PC must be equipped with the USB 2 0 and one of the following operating systems MAC OS X v10 5 8 or higher version Windows 7 Windows Vista or Windows XP Home or Professional SP3 SD Ca...

Page 150: ...er supply 18 30Vdc Stand by absorption 100 mA 30V Max operating absorption 200 mA 30V Operating temperature 10 40 C LCD display size 10 2 LCD display resolution 800 x 480 Supported SD CARD 32 Gb maxim...

Page 151: ...ration MODE 1 and configuration MODE 2 The main characteristics for each configuration mode are listed below POSITION Mode 1 Mode 2 F FF FF F I II II I I Default for II is 04 need not connect the conf...

Page 152: ...inition of area 5 to area 8 Area1 to area 4 can t be changed Status display the detector status when it becomes blue detector is enabled and when it becomes gray means disabled Areas show area1 to are...

Page 153: ...ot to insert configurator 0 I 6 I 0 It is ok not to insert configurator 0 I 8 Configuration setting by inserting phisical configurators WAY 2 Side pushbutton functions SOS Key in case of urgent or une...

Page 154: ...emusic and photos PC must be equipped with the USB 2 0 and one of the following operating systems MAC OS X v10 5 8 or higher version Windows 7 Windows Vista or Windows XP Home or Professional SP3 SD C...

Page 155: ...Flush mounting installation with dedicated box supplied with the product Technical data Power supply 30Vdc Stand by absorption 110 mA 30V Max operating absorption 290 mA 30V Camera diagonal view angle...

Page 156: ...d II choose the biggest number II of system then calculate total IU number of system If the total number FF II R is less or equal 4000 use of MODE 2 is suggested MODE 1 example Entrance panel must be...

Page 157: ...e anti removal alarm pushbutton By selecting this function and pressing the anti removal alarm button the entrance panel automatically send a removal alarm If a wrong alarm is sent due to A wrong sett...

Page 158: ...the setting interface the configuration parameters of the current entrance panel will appear To make changes enter the desired number in serial order After entering the 8 digit number just press to c...

Page 159: ...e as follows Position Value for configurator RemarkS N 0 0 N 5 F FF is 20 default No need for configuration F I II is 4 default No need for configuration I Example B EPaddress eachriserhas25floors and...

Page 160: ...using SF2 Software and PC connection WAY 3 WARNING in order for the communication to take place the EP must be powered and not physically configured The entrance panel has two video compensation gear...

Page 161: ...sponding numerical code you must know the resident code Flush mounting installation with dedicated box supplied with the product Related items 322012 Targa module 346250 Door lock relay Technical data...

Page 162: ...ce panel camera and compensation Lamp connector 6 RJ45 Targa module connection 7 RJ45 System BUS connection 8 6 poles connector 12V GND power supply for access control module Optional UNLOCK signal ou...

Page 163: ...using SF2 Software and PC connection Configuration settings by device keyboard WAY 1 PASSWORD Access to the configuration men by press and hold the door lock key for more than 10 seconds Enter the ac...

Page 164: ...p To change the access password press OK than enter new password 6789 Confirm by pressing Entrance panel settings Select the menu function and confirm by pressing Device settings submenu allows you to...

Page 165: ...h Press to select the text field Enter the message text by using the alphanumerical keyboard in the same way as you write an SMS on your mobile phone Than confirm with The message will continuously ap...

Page 166: ...the type of code to be used to call the resident Apart address SCS address of the handset Call mode Numerical code assigned to the resident Calling mode recall when this function is enabled the entran...

Page 167: ...nts in the address book For each resident is possible to set the following parameters ID Number identification progressive number automatically assigned by the device to each resident This function gi...

Page 168: ...ts present in the addresses book address book New contact Modify contact Delete contact del this contact Confirm Will be deleted EXIT del address book Confirm Will be deleted EXIT Aaaaa Bbbbb Ccccc Dd...

Page 169: ...present Signal type of lock NO Normally open NC Normally closed Dismantle alarm ON alarm enabled OFF alarm disabled Digital colour entrance panel with addresses list 322011 Firmware version this menu...

Page 170: ...rface Configuration by using SF2 Software and PC connection WAY 2 WARNING in order for the communication to take place the EP must be powered and not physically configured The entrance panel has a dou...

Page 171: ...nstallation flushmountedboxsuppliedwiththeproduct Whitenight backlit Protection degree IP54 protection index against mechanical impact IK07 Power supply 30Vdc Stand by absorption 5 mA 30V Max operatin...

Page 172: ...resolution 512 x 582 Camera diagonal view angle 70 Camera distance up to clear picture 40 50 cm Camera minimum lux level visibility 0 5 Lux Operating temperature 25 55 C Protection index IP 54 Protec...

Page 173: ...the product Flush mounting installation with dedicated box supplied with the product Related items 322032 additional 16 pushbuttons panel Technical data Power supply 30Vdc Stand by absorption 14 mA 30...

Page 174: ...this status In setting status entrance panel can t call and work with internal unit but can set room number or SCS address of corresponding pushbutton After finished set exit setting status by jumper...

Page 175: ...anel must be powered and NOT phisically configured 323020 configuration tool Distance 1 2 0 300 m OFF OFF 300 700 m ON OFF 700 1000 m ON ON The entrance panel has two video compensation gears we can l...

Page 176: ...select RM enter room number mode insert configurators 02 in FF sockets and configurators 03 in II sockets and insert configurators 06 in I I press the 1st pushbutton left on the front of the panel A...

Page 177: ...the product Flush mounting installation with dedicated box supplied with the product Related items 322033 additional 32 pushbuttons panel Technical data Power supply 30Vdc Stand by absorption 14 mA 3...

Page 178: ...rance panel can t call and work with internal unit but can set room number or SCS address of corresponding pushbutton After finished set exit setting status by jumper insertion NA By inserting jumper...

Page 179: ...jumper select CF enter setting status jumper select RM enter room number mode insert configurators 02 in FF sockets and configurators 03 in II sockets and insert configurators 06 in I I press the 1st...

Page 180: ...anel must be powered and NOT phisically configured Distance 1 2 0 300 m OFF OFF 300 700 m ON OFF 700 1000 m ON ON The entrance panel has two video compensation gears we can let the video signal output...

Page 181: ...icated box supplied with the product Related items 322030 10 pushbuttons colour video entrance panel Technical data Power supply 30Vdc Stand by absorption 5 mA 30V Max operating absorption 28 mA 30V O...

Page 182: ...n work status as for below table Configuration settings by inserting physical resistor configuration WAY 1 Factory default is room number See pushbutton corresponding room number as follows Setting of...

Page 183: ...ng is wrong We cannot set FF and II as 00 repeat this setting sequence for all pushbuttons At the end insert a jumper between NA pins The setting procedure is finished Setting of ROOM NUMBER or SCS AD...

Page 184: ...h dedicated box supplied with the product Related items 322031 20 pushbuttons colour video entrance panel Technical data Power supply 30Vdc Stand by absorption 5 mA 30V Max operating absorption 28 mA...

Page 185: ...ult number is 01 NOTE B the additional pushbuttons panel number MUST BE the same as for the associated main entrance panel POSITION VALUE FOR CONFIGURATOR REMARKS N 0 NN is 01 default When no jumper o...

Page 186: ...heard three short tones it means that setting is wrong We cannot set FF and II as 00 repeat this setting sequence for all pushbuttons At the end insert a jumper between NA pins The setting procedure...

Page 187: ...ed Wall mount installation Technical data Power supply 30Vdc Stand by absorption 30 mA 30V Max operating absorption 70 mA 30V Operating temperature 10 40 C Dimensional data Legend 1 Handset 2 Door loc...

Page 188: ...ber will be saved otherwise 3 short beeps will be heard and the number will be not saved Exit 1 Press the door lock release pushbutton to move to the last item Press the door lock release pushbutton a...

Page 189: ...bmenu Press the door lock release pushbutton to move to the next setting position the order is tens units exit current setting item back to initial installation setup status After moving to that posit...

Page 190: ...0 the handset is unable to use the doorbell function and the message light is off During setup the parameter will be saved automatically Exit 1 Press the door lock release pushbutton to exit the curre...

Page 191: ...ring tones selectable for different call types Surge protection Wall mount installation Technical data LCD display resolution 480 x 234 Power supply 30Vdc Stand by absorption 20 mA 30V Max operating a...

Page 192: ...f FF in whole system is more than 20 or the biggest number of II is more than 4 we suggest to use MODE 2 configuration to setup FF choose the biggest number FF of system and II choose the biggest numb...

Page 193: ...le only when the function is set as Small EP function 0 Shielded handset can not monitor Small EP message light off 1 long tone return to main menu of installation setting 1 short tone other unsuccess...

Page 194: ...pens 25 The light of defence area give the parameter For example if the parameter is 3 then LED 3 will on 1 delay 40 s 1 long tone only LED 1 will on Default 40 s only for thief area alarm 2 delay 100...

Page 195: ...nfigurator 0 I 4 I Because the default value of II is 4 no configurator is needed I Example B The number of handsets is 1206 each floor has 8 handsets System configuration mode 2 is used The handset c...

Page 196: ...NO C NO C 10 K 10 K Fn GND NO C sensor 8 sensor 7 sensor 6 sensor 5 gas sensor smoke sensor door sensor infrared sensor 10 K 10 K NO C NC 12 V GND 12 V F1 GND F8 F7 F6 F5 F4 F3 F2 10 K 10 K Fn GND NC...

Page 197: ...4 SENSOR 4 GAS SENSOR F5 SENSOR 5 Theft alarm Infrared or non infrared Default is infrared sensor User can set it to be non infrared Can use short key to sensor active or idle F6 SENSOR 6 Infrared or...

Page 198: ...o F12 18 User defined keys F01 to F06 19 Loudspeaker Porter switchboard D45 System table top porter switchboard device with high resolution 7 LCD display and icons men Able to communicate with handset...

Page 199: ...l setting Two different device configuration ways available WAY 1 configuration settings by device icons on screen men WAY 2 configuration by using SF4 323012 Software and PC connection Configuration...

Page 200: ...HANDSET other Switchboard address or by address book 3 User defined function shortcut keys 12 user defined key enabling the user to call handsets EPandotherSwitchboardatthepressofabutton Entrustedorno...

Page 201: ...ysteminterfacedeviceusedtoconvertvideosignalsontheBUSandthendistribute themtotheconnectedhandsets Devicetobeinstalledbetweenfloors Eachfloorshunt can be connected to 4 handsets Equipped with video gai...

Page 202: ...D45 system interface device used to connect riser BUS and system BUS in order to separate BUS transfer signal and switch between video and audio channels The device has five RJ45 connectors which are...

Page 203: ...00 IUs Two different configuration modes available for whole system configuration MODE 1 and configuration MODE 2 The main characteristics for each configuration mode are listed below When the biggest...

Page 204: ...d For configuration MODE 1 and MODE 2 if riser shunt chooses configuration by configurator following conditions must be met Number of all the riser shunt in the system should be running number sequent...

Page 205: ...m 5 entrance panels The video transfer distance can be adjusted by setting the gain adjustment DIP SWITCH DIN RAIL installation Possibility to connect in cascade several entrance panel video mixer Tec...

Page 206: ...Terminal rated output current 0 5 A Operating temperature 10 40 C Dimensional data Upper view Internal view Legend 1 External battery connection optional 2 Power output connection 3 ON OFF Switch 4 A...

Page 207: ...device power supply type system supply additional supply alarm current that power supply offers to each IU enable or disable smart power supply and PWmanagementandselectsystemconfigurationmode Onlywi...

Page 208: ...having standby battery OPTIONAL when A C is cut IU will be informed to enter enery saving mode to save energy for alarm function For system with alarm function and battery is suggested to set power su...

Page 209: ...supply configuration should be as following Position Mode 1 Value for configurator RemarkS CF1 N 0 CF2 N 1 CF3 N 2 CF4 FF Min 0 CF5 FF Min 1 CF6 II Default is 4 apartments 0 means 4 apartments0 CF7 II...

Page 210: ...owerfunctionandpowermanagementfunction thepowersupply address is 12 max current of alarm sensor is 300 mA System use MODE 2 configuration method Power supply configuration should be as following Posit...

Page 211: ...guration Note X means no need any configurator it also means the configurating position is 0 others need configurator with requested value means need configuration here Configuration No system PWS Sol...

Page 212: ...connect the porter switchboard and extend the switchboard installation in this case if the switchboard is fitted with a camera the video signal cannot be transmitted to the handset DIN RAIL installat...

Page 213: ...nical data Power supply 30Vdc Stand by current absorption 40 mA 30V Max operating current absorption 140 mA 30V Stand by power consumption 1 2W Operating power consumption 4 2W Operating temperature 1...

Page 214: ...hen calculate total IU number of system If the total number FF II R is less or equal 4000 use of MODE 2 is suggested Two different device configuration ways available WAY 1 Configuration settings by i...

Page 215: ...CF3 II II II means the Device apartment number Tens at the front CF4 CF5 II If we have four households on each floor tens at the front II is for 0 or no configuration resistor the default is 4 househo...

Page 216: ...1 Remarks we suggest to use auxiliary power supply If the power consumption of five indoor units is not more than the supply of one power supplier then these five indoor units can be all set as the m...

Page 217: ...hrough the unit BUS system only one indoor unit can be set as the master indoor unit handset handset handset handset handset To HANDSET 2 To HANDSET 3 To HANDSET4 System output connect to 323002 input...

Page 218: ...voltage 100 265Vac Rated output voltage 30 5Vdc 0 5V Rated output current 2 A 30V Operating temperature 10 40 C Dimensional data Upper view Legend 1 External battery connection optional 2 Power outpu...

Page 219: ...y absorption 130 mA 30V Max operating absorption 230 mA 30V Operating temperature 10 40 C Dimensional data Front view Legend 1 Configurators housing 2 USB interface port for configuration download and...

Page 220: ...Riser 5 320 399 Riser 6 400 479 Riser 7 480 559 ConnectforUSBdownloadconfiguration Connectforserialportdownloadconfiguration ConnectfortheEthernetdownloadconfiguration D45 IP interface has three ways...

Page 221: ...n 3W Operating power consumption 9W Operating temperature 10 40 C Dimensional data Front view Legend 1 RJ45 D1 connector riser shunt branch 1 connection 2 RJ45 D2 connector riser shunt branch 2 connec...

Page 222: ...re than 4 we suggest to use MODE 2 configuration to setup FF choose the biggest number FF of system and II choose the biggest number II of system then calculate total IU number of system If the total...

Page 223: ...to install the main EP and the switchboard Below diagram 1 3 District generator configuration example Backbone main EP 1 Switchboard 6 Position Field Name 1 DistricT generator 2 DistricT generator 3...

Page 224: ...istrict generator layer branch could be extended to install the main EP and switchboard also using the EP switchboard shunt Below diagram 1 3 District generator configuration example Position Field Na...

Page 225: ...r layer to installWEP and Switchboard Below diagram 1 3 DH1 configuration as an example Position Field Name 1 District generator 2 District generator 3 District generator Remark CF1 EPS 0 0 0 NULL mea...

Page 226: ...of needs DIN RAIL installation Technical data Power supply 30Vdc Stand by current absorption 30 mA 30V Max operating current absorption 30 mA 30V Stand by power consumption 0 9W Operating power consu...

Page 227: ...23015 322010 Door lock accessory Limit distance 250 m Manual pushbutton Line specification RVV2 x 1 0 mm2 Electronic lock Line specification RVV2 x 1 0 mm2 Wiring connection with digital call entrance...

Page 228: ...0 323005 323015 322020 322050 Door lock accessory Limit distance 250 m Manual pushbutton Line specification RVV2 x 1 0 mm2 Electronic lock Line specification RVV2 x 1 0 mm2 Wiring connection with smal...

Page 229: ...in the villas area DIN rail installation Technical data Power supply 30Vdc Stand by current absorption 20 mA 30V Max operating current absorption 160 mA 30V Stand by power consumption 0 6W Operating...

Page 230: ...hedetachedvillaisonlyfittedwithonehandset thiscanbeconnectedtofloor shunt If there are 2 to 5 handsets one apartment interface needs to be added for expansion and the Small EP must be connected to the...

Page 231: ...I U 2 I U 3 V G A IN V C C O U T G N D B A T T B A T T U T 1 O U T 2 O U T 3 V C C O U T G N D B A T T B A T T U T 1 O U T 2 O U T 3 323002 323002 323010 323010 323016 323003 323005 Villa shunt Syste...

Page 232: ...ng key of lift 4 Relay OUTPUT 7 connect to the corresponding key of lift 5 Relay OUTPUT 6 connect to the corresponding key of lift 6 Relay OUTPUT 5 connect to the corresponding key of lift 7 Relay OUT...

Page 233: ...CF5 CF6 must be 8 2 Entrance panel calls internal unit and internal unit unlock the output relay connected to the floor entrance panel act after delay time the output relay connected to the floor int...

Page 234: ...ted to manage this system By setting delay time to 10 seconds CF7 1 the configuration values of the two interfaces will be as follows Configuration WARNINGS OUTPUT 1 to 5 will manage the corresponding...

Page 235: ...means N 1 The phisical configuration value means the channel number WARNING By this configuration method DEVICE 1 OUTPUT 1 will manage the 2 entrance panels EP with address 1 and 2 of the underground...

Page 236: ...CONFIGURATION BY USING SF2 SOFTWARE AND PC CONNECTION WAY2 This is the SUGGESTED enhanced way to download the device configuration to the lift control interface device previously created by using SF2...

Page 237: ...UT2 OUTPUT3 OUTPUT4 OUTPUT5 OUTPUT6 OUTPUT7 OUTPUT8 OUTPUT1 OUTPUT2 OUTPUT3 OUTPUT4 OUTPUT5 OUTPUT6 OUTPUT7 OUTPUT8 OR EP1 C F 1 C F 2 C F 3 C F 4 C F 5 C F 6 C F 7 0 2 0 4 7 1 1 1 M C F 1 C F 2 C F 3...

Page 238: ...UTPUT2 OUTPUT3 OUTPUT4 OUTPUT5 OUTPUT6 OUTPUT7 OUTPUT8 OR OR OR EP3 EP5 OR OR EP4 EP1 EP2 1 2 3 4 323004 C F 1 C F 2 C F 3 C F 4 C F 5 C F 6 C F 7 0 2 0 4 8 0 2 1 M C F 1 C F 2 C F 3 C F 4 C F 5 C F 6...

Page 239: ...ng current absorption 70 mA 30V Stand by power consumption 2 1W Operating power consumption 2 1W Operating temperature 10 40 C Dimensional data Legend 1 Configurators housing 2 Serial port interface f...

Page 240: ...evice wiring direction must satisfy the following rules or they will lead to irregular working of the system 1 Riser shunt must be connected at the B1 connector interface of all interface in the relev...

Page 241: ...enhanced way to download the device configuration to interface device previously created by using SF2 configuration software and a personal computer To transfer file use the configurator hardware too...

Page 242: ...on 50 mA 30V Max operating current absorption 80 mA 30V Stand by power consumption 1 5W Operating power consumption 2 4W Operating temperature 10 40 C Dimensional data Legend 1 Serial port interface f...

Page 243: ...C 8 pole flat cable CD ROM containing SF2 devices configuration and driver softwares Dimensional data Legend 1 USB 2 0 connector 2 TX LED Green flashing transmitted data 3 UART connector 4 Not used 5...

Page 244: ...ase easy installable inside the system junction boxes RJ45 adapter is supplied with the device Power supply 18 30Vdc Stand by absorption 10 mA 30V Max operating absorption 100 mA 30V Operating tempera...

Page 245: ...temperature 10 40 C Dimensional data Legend 1 Configurators housing 2 ISP serial interface connector for PC configuration and firmware update 3 Internal unit or 323009 apartment interface connector 4...

Page 246: ...CF2x 4 CF3x 2 CF4 x 1 1 For example when CF1 0 CF2 0 CF3 1 and CF4 1 the number of connected SEPs is 0 x 8 0 x 4 1 x 2 1 x 1 1 4 units Code switches CF1 CF2 CF3 CF4 are also used to set the SEPs exte...

Page 247: ...TCH CF5 CF6 CF7 CF8 as for the following table DIP position CF5 First lock CF6 Second lock CF7 Third lock CF8 Fourth lock ON Negative lock Negative lock Negative lock Negative lock OFF Positive lock P...

Page 248: ...and double press the monitor key again to monitor the second SEP 2 and so on Monitoring sequence as follows ONE LEVEL SYSTEM CONNECTION SEQUENCE 1 2 3 4 TWO LEVELS SYSTEM CONNECTION SEQUENCE 1 A 1 B 1...

Page 249: ...r cascade connections SEP Video mixer 323023 Small entrance panel video mixer Wiring diagram 2 Limit Distance Max A 200 m RVV X 0 5 Max B 100 m RVV X 0 5 Max C 200 m RVV X 0 5 RVV cable and coaxial ca...

Page 250: ...P 4 323023 Small entrance panel video mixer Wiring diagram 3 Limit Distance Max B 100 m RVV X 0 5 Max D 200 m Cat5 Max E 200 m RVV X 0 5 B B B B 323023 D E Cat5 cable BT00856 a EN 03 09 2014 Apartment...

Page 251: ...el video mixer Wiring diagram 4 Limit Distance Max B 100 m RVV X 0 5 Max C 200 m RVV X 0 5 Max D 200 m Cat5 Max E 200 m RVV X 0 5 Apartment Interface 323009 D Cat5 cable 323023 E 323023 323023 323023...

Page 252: ...chnical data Power supply 30Vdc Stand by absorption 1 mA 30V Max operating absorption 20 mA 30V Operating temperature 10 40 C Dimensional data Front view Legend 1 INT connection is the device external...

Page 253: ...configuration When the 346858 floor is 10 F and the first household then its configuration can be made like follows ConfigURATION place Simple configuration Mode 1 CF1 FF 17 CF2 CF3 II 02 CF4 CF5 Defa...

Page 254: ...national Department 87045 Limoges Cedex France 33 0 5 55 06 87 87 Fax 33 0 5 55 06 74 55 Follow us also on www legrand com www youtube com user legrand www facebook com Legrand twitter com legrand_new...

Reviews: