156
322010
1 2
ON
OFF
S- S+
C
NC NO
L+ L-
NO
NC
C
322010
346250
Digital colour entrance panel
Distance
1
2
0 –300 m
OFF
OFF
300 – 700 m
ON
OFF
700 – 1000 m
ON
ON
This is the enhanced way to download the device configuration to entrance panel
previously created by using SF2 configuration software and a personal computer. To
transfer use the configuration hardware tool 323020 serial interface
Configuration by using SF2 Software and PC connection -
WAY 3
:
WARNING : in order for the communication to take place, the EP must be powered and
not physically configured
The entrance panel has two video compensation gears. By setting different V-GAIN
gears, we can let the video signal output adapt to different transmission distance. See
followings:
DIP SWITCH SETTINGS FOR B/W. AND COLOUR SYSTEM
Configuration
Wiring diagrams - Door lock relay connection
323020
configuration
tool
video gain setting
N.B.: Cable size 1 mm
2
and max distance 2 meters
8A cos
ϕ
= 1
24 Vac/24 Vdc
4A cos
ϕ
= 0.7 24 Vac
3A cos
ϕ
= 0.4 24 Vac
BT00466-b-en