175
322031
→
504
→
502
→
404
→
402
→
304
→
302
→
204
→
202
→
104
→
102
503
←
501
←
403
←
401
←
303
←
301
←
203
←
201
←
103
←
101
←
SCS rM CF NA
SCS rM CF NA
SCS rM CF NA
20 Pushbuttons colour video entrance panel
Configuration
Configuration settings by inserting physical resistor configuration - WAY 1:
Factory default is room number, see pushbutton corresponding room number as follows:
BT00766-a-en
03/06/2013
Setting of entrance panel number :
Jumper select (NA) enter work status - insering the jumper between (
NA pins
),
NN
configurators indicates the entrance panel number (range from 01 to 80).
Example - set the entrance panel number as 03:
while entrance panel power supply is OFF, insert a jumper between NA pins, put
configurators 03 in NN sockets. Then put power supply ON, the entrance panel will save
the 03 number.
NOTE (A)
: phisical configurator insertion has higher priority. If NO configurator
inserted, the EP number is the last value we got by configurators or by SF2 software.
Default number is 01.
NOTE (B)
: the entrance panel number MUST BE the same as for the associated ad-
ditional pushbutton panel.
Assign room number or SCS address for each pushbutton
room mode number
First select (CF) entering setting status, than select (RM) entering room number mode,
insert configurators, last press the pushbutton which you want to set in the front of the
panel until a long tone be heard. A long tone will indicates that room number has been
successfully completed.
Repeat configurators insertion to set all room number corresponding pushbutton.
After finished to set all room number, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 203 - number of aparments per floor = 06 :
- jumper select (CF) enter setting status, jumper select (RM) enter room number mode
- insert configurators 02 in FF sockets and configurators 03 in II sockets and insert
configurators 06 in #I #I
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (We cannot set
FF and II as 00).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
POSITION
VALUE FOR CONFIGURATOR
N
0
N
6
F
0
F
2
I
0
I
3
POSITION
VALUE FOR CONFIGURATOR
N
N
F
0
F
1
I
2
I
3
(SCS)
- SCS address mode
(rM)
- Room number mode
(CF)
- Setting status
(NA)
- Work status
SCS address mode (direct call mode)
First, jumper select (CF) entering setting status, than jumper select (SCS) entering SCS
address mode. Insert configurators, last press the pushbutton which you want to set in
the front of panel until a long tone be heard. A long tone will indicates SCS address has
been successfully completed.
Repeat configurators insertion to set all SCS address corresponding pushbutton.
After finished to set all SCS address, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 0123:
- jumper select (CF) enter setting status, jumper select (CF) enter SCS address mode
- insert configurators 0123 in FFII sockets
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (Max. SCS
configuration address is 4000).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of porter switchboard call :
same procedure as for the SCS address mode setting but porter switchboard address is
fixed to 4000. Means that FFII must be set as 4000.
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...