
185
322040
Audio indoor handset
Set maximum apartments quantity per floor in a riser (#I #I)
Set external SOS contact to be NO/NC
Example 2
:
Once in the initial installation setup status press and hold call to the switchboard 5
times. If SOS status is the default parameter, the message light will be ON, which means
the SOS is always ON. Press the switchboard pushbutton once, message light will go OFF,
which means SOS will be always OFF. Press the switchboard pushbutton once, message
light will go ON, which means SOS will be always ON. Other operation may be deducted
by analogy. Finally, press the door lock release pushbutton to exit the initial installation
setup status. Once in the initial installation setup status press and hold the door lock
release pushbutton to exit the installation setup status and return to standby status.
FUNCTIONS
OPErATION
rEMArkS
Enter setup submenu for number of
households per floor
While in the initial installation setup status, press and hold the switchboard pushbutton twice to enter the
setup submenu for the apartments quantity per floor. Note: the first number to set after entering the submenu
is the tens position.
The number of households per floor cannot be
less than the household number. the range is
1-99. The default number is 4.
Set the parameter
Press the switchboard pushbutton to add 1 unit to the relevant position. If the pushbutton is pressed after
the input parameter has reached 10, 3 short beeps will indicate wrong operation and the device will exit the
apartments quantity setup submenu automatically and return to the initial installation setup status.
Select setting item and exit the submenu Press the door lock release pushbutton to move to the next setting position, the order is: tens- units-exit
current setting item, back to initial installation setup status. After moving to that position, the parameter of
that position will be 0. Before exiting, please check if the setting parameter is correct. If correct, a long beep
will be heard and the set parameter will be saved. Otherwise, 3 short beeps will be heard and the parameter
will not be saved.
Exit
1) Press the door lock release pushbutton to move to the last item. Press the door lock release pushbutton
again to exit the current submenu and return to the initial installation setup status.
2) If the operation is performed wrongly, 3 short beeps will be heard the unit will automatically return to the
initial installation setup status.
FUNCTIONS
OPErATION
rEMArkS
Select the setup submenu for SOS NO/NC While in the initial installation setup status, press and hold the switchboard pushbutton five times to enter the
setup submenu for SOS NO/NC. Read the current parameter. If it’s NO, the parameter is 1 and the message light
will be on. If it’s NC, the parameter is 0 and the message light will be off.
Default: always on
Set the parameter
Press the call to the switchboard pushbutton to increase the parameter by 1. The parameter will return to 0
after it reaches to 2. When parameter is 1, SOS is NO type, and the message light is also on. When parameter is
0, SOS is NC type, and message light is also off. During setup the parameter will be saved automatically.
Exit
1) Press the door lock release pushbutton to exit the current submenu and return to the initial installation
setup status.
2) If the operation is performed wrongly, 3 short beeps will be heard the unit will automatically return to the
initial installation setup status.
BT00471-b-en
30/05/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...