241
1#
2#
3#
4#
141 mm
33 mm
105 mm
94 mm
128.2 mm
7
8
9
10
11
12
13
14
15
1#
2#
3#
4#
1
2
3
4
5
6
323023
D45 System
Small entrance panel
video mixer
BT00856-a-en
03/09/2014
Description
D45 System interface device to be used to connect and switch multiple SEP (Small
Entrance Panel). Generally is possible to connect 4 SEPs but in some special cases you
can connect (by cascade connection - max. 2 levels) up to 16 SEPs. Settings by an 8
positions DIP SWITCH.
Technical data
Power supply:
18 - 30 Vdc
Stand by absorption:
≤ 15 mA @ 30 V
Max operating absorption:
≤ 1 A@30 V
Stand by power consumption: ≤ 0.45 W
Operating power consumption: ≤ 30 W
Door lock maximum current : 400 mA
Operating temperature : (-10) - (+40)°C
Dimensional data
Legend
1.
Configurators housing
2.
(ISP) serial interface connector for PC configuration and firmware update
3.
Internal unit or (323009) apartment interface connector
4.
8 positions SETTINGS DIP SWITCH
5.
Power supply LED
6.
Conversation status LED
7.
(
SEP 4
) SEP 4 door lock (L- L+) or (323015) door lock accessory connection
8.
(
SEP 4
) small entrance panel 4 (R1-R2-R3-R4) input connector
9.
(
SEP 3
) SEP 3 door lock (L- L+) or (323015) door lock accessory connection
10.
(
SEP 3
) small entrance panel 3 (R1-R2-R3-R4) input connector
11.
(
SEP 2
) door lock (L- L+) or (323015) door lock accessory connection
12.
(
SEP 2
) small entrance panel 2 (R1-R2-R3-R4) input connector
13.
(
SEP 1
) door lock (L- L+) or (323015) door lock accessory connection
14.
(
SEP 1
) small entrance panel 1 (R1-R2-R3-R4) input connector
15.
Auxiliary power supply input connector (30 V)
Front view
Lower view
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...