Additional 32 call pushbuttons panel
Configuration
Configuration by using SF2 Software and PC connection- WAY 2 :
This is the enhanced way to download the device configuration to additional pushbut-
tons panel previously created by using SF2 configuration software and a personal
computer. To transfer use the configuration hardware tool 323020 serial interface
WArNINg : to ensure that the communication is successful, additional pushbut-
tons panel must be powered and NOT phisically configured.
323020
configuration
tool
BT00768-a-en
03/06/2013
room mode number
First select (CF) entering setting status, than select (RM) entering room number mode,
insert configurators, last press the pushbutton which you want to set in the front of the
panel until a long tone be heard. A long tone will indicates that room number has been
successfully completed.
Repeat configurators insertion to set all room number corresponding pushbutton.
After finished to set all room number, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 203 - number of aparments per floor = 06 :
- jumper select (CF) enter setting status, jumper select (RM) enter room number mode
- insert configurators 02 in FF sockets and configurators 03 in II sockets and insert
configurators 06 in #I #I
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (We cannot set
FF and II as 00).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of rOOM NUMBEr or SCS ADDrESS for each pushbutton
POSITION
VALUE FOR CONFIGURATOR
N
0
N
6
F
0
F
2
I
0
I
3
(SCS)
- SCS address mode
(rM)
- Room number mode
(CF)
- Setting status
(NA)
- Work status
POSITION
VALUE FOR CONFIGURATOR
N
N
F
0
F
1
I
2
I
3
SCS address mode (direct call mode)
First, jumper select (CF) entering setting status, than jumper select (SCS) entering SCS
address mode. Insert configurators, last press the pushbutton which you want to set in
the front of panel until a long tone be heard. A long tone will indicates SCS address has
been successfully completed.
Repeat configurators insertion to set all SCS address corresponding pushbutton.
After finished to set all SCS address, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 0123:
- jumper select (CF) enter setting status, jumper select (CF) enter SCS address mode
- insert configurators 0123 in FFII sockets
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (Max. SCS
configuration address is 4000).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of porter switchboard call :
same procedure as for the SCS address mode setting but porter switchboard address is
fixed to 4000. Means that FFII must be set as 4000.
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...