166
S- S+ C
NC NO
L+ L-
NO
NC
C
323020
configuration
tool
1 2
ON
OFF
322011
Digital colour entrance panel
with addresses list
322011
346250
Distance
1
2
0 –300 m
OFF
OFF
300 – 700 m
ON
OFF
700 – 1000 m
ON
ON
This is the enhanced way to download the device configuration to entrance panel
previously created by using SF2 configuration software and a personal computer. To
transfer use the configuration hardware tool 323020 serial interface
Configuration by using SF2 Software and PC connection -
WAY 2
:
WARNING : in order for the communication to take place, the EP must be powered and
not physically configured
The entrance panel has a double DIP SWITCH for the video compensation setting.
By setting different DIP V-GAIN, it is possible to adapt the video signal to different
transmission distances - refer as follows :
DIP SWITCH SETTINGS FOR B/W. AND COLOUR SYSTEM
Configuration
Wiring diagrams - Door lock relay connection
N.B.: Cable size 1 mm
2
and max distance 2 meters
8A cos
ϕ
= 1
24 Vac/24 Vdc
4A cos
ϕ
= 0.7 24 Vac
3A cos
ϕ
= 0.4 24 Vac
Video gain settings
BT00853-a-en
03/09/2014