218
323013
ON
1 2 3 4
ON
OFF
EPS EPS mc
min
mc
min
mc
max
mc
max
P/S cF8 cF9 cF10
EPS EPS mIN mIN mAXmAX P/S
District generator
Video gain settings
The video gain setting can be divided into 5 branches: branch1, branch 2, branch 3,
branch 4, wall EP. They can all be set according to the instruction data in following table.
However, these data may be different during actual installation. To adjust and set the
data take into account the actual image.
Distance
1
2
3
4
Colour
video
signal
0 – 300 m
OFF
OFF
OFF
OFF
300 – 700 m
ON
OFF
OFF
OFF
700 – 1000 m
ON
ON
OFF
OFF
B/W
video
signal
1000 –1500 m
ON
ON
ON
OFF
1500 – 2000 m
ON
ON
ON
ON
Configuration
Two
different configuration modes available for whole system
:
configuration
MODE 1
and configuration
MODE 2
. The main characteristics for each
configuration mode are listed below.
When the biggest number of #FF in whole system is ≤ 20, and the biggest number
of #II is ≤4, and the total risers number is ≤ 50, we recommend to choose (
MODE 1
)
configuration for system.
When the biggest number of #FF in whole system is more than 20, or the biggest
number of #II is more than 4, we suggest to use (
MODE 2
) configuration to setup #FF
(choose the biggest number #FF of system) and #II (choose the biggest number #II of
system), then calculate total IU number of system. If the total number (#FF * #II * R ) is
less or equal 4000, use of (
MODE 2
) is suggested.
Two different device configuration ways available:
WAY 1
) Configuration settings by inserting phisical configurators
WAY 2
) Configuration by using SF2 Software and PC connection
Configuration by inserting phisical configurators - WAY 1:
Meaning of the configuration places:
POSITION MODE 1
CF1
EPS
If 323013 is primary. EPS must be set as Max WEP address on WEP port
If 323013 is secondary. EPS must be set as Max WEP address on MC port
CF2
CF3
MC
Min
Set Switchboard address range
CF4
CF5
MC
Max
CF6
CF7
P/S
0: primary 323013
1: secondary 323013
Configuration by using SF2 software and PC connection - WAY 2:
This is the enhanced way to download the device configuration to interface device
previously created by using SF2 configuration software and a personal computer. To
transfer file use the configurator hardware tool 323020 serial interface.
WArNINg
: in order for the communication to take place, district generator device must
be powered and not physically configured.
323020
configuration
tool
BT00460-b-en
13/05/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...