Example (C):
If necessary enable the smart
power function, no need for the
power management function (if no
management function, the power
supply address does not need
to be set), the range of handset
addresses managed by the power
supply is 125-163.
Without alarm, it means that the
current of alarm sensor is 0 mA. The
system used Mode 3 configuration.
The power supply configuration
should be as follows:
poSition
Mode 1
Value for
configurator
reMarkS
CF1
N
0
CF2
N
0
CF3
N
0
CF4
FF Min
0
CF5
FF Min
1
CF6
#II
2
CF7
#II
5
CF8
FF Max
0
CF9
FF Max
1
CF10
CF10
6
CF11
CF11
3
CF12
Type
2
CF13
ASR
1
CF14
M
1
CF15
LE
0
C
53
GUIDE
D45 SyStEm
WWW.LEGRAND.COM