GENERAL RULES FOR INSTALLATION
Example (B):
This riser has 20 floors, and each floor
has 5 handsets. This power supply
manages 1-2 floors.
If necessary enable the smart power
function and the power management
function, the power supply address
is 12, max current of the alarm sensor
is 300 mA. System configuration
Mode 2 is used. The power supply
configuration should be as follows:
poSition
Mode 1
Value for
configurator
reMarkS
CF1
N
0
CF2
N
1
CF3
N
2
CF4
FF Min
0
CF5
FF Min
1
CF6
#II
0
CF7
#II
5
CF8
FF Max
0
CF9
FF Max
2
CF10
CF10
Here configuration is not necessary for
Mode 1 and Mode 2
CF11
CF11
CF12
Type
1
CF13
ASR
0
CF14
M
0
CF15
LE
0
B
Accessory configuration examples