Digital colour entrance panel
Legend
1.
NN #FF #II: configurators housing
2.
ISP: entrance panel software upgrade connector
3.
SPK: loudspeaker volume adjust
4.
MIC: microphone volume adjust
5.
VIDEO-IN/GND/NC/+12V/LED : entrance panel camera and compensation Lamp
connector
6.
RJ45 SYSTEM BUS connector
7.
7 poles connector for :
– +12V/GND power supply for access control module (Optional)
– UNLOCK signal output from access control module (Optional)
– GND/DAS electronic lock status signal connector
– LOCK-/LOCK+ electrical door lock connection
8.
SPK-OUT/GND/GND/SPK-OUT: entrance panel loudspeaker connections
9.
DIP SWITCH for video gain setting - see specific section
10.
ANT access control antenna module connection (Optional)
11.
RESET - Password reset pushbutton
Configuration
When the biggest number of #FF in whole system is ≤ 20, and the biggest number
of #II is ≤4, and the total risers number is ≤ 50, we recommend to choose (
MODE 1
)
configuration for system.
When the biggest number of #FF in whole system is more than 20, or the biggest
number of #II is more than 4, we suggest to use (
MODE 2
) configuration to setup #FF
(choose the biggest number #FF of system) and #II (choose the biggest number #II of
system), then calculate total IU number of system. If the total number (#FF * #II * R ) is
less or equal 4000, use of (
MODE 2
) is suggested.
MODE 1 example
Entrance panel must be configured for following parameters:
NN : Entrance panel number
# FF : Floor quantity in a riser
# II : Maximum apartment quantity per
floor in a riser
Two different configuration modes available for whole system :
configuration MODE 1 and configuration MODE 2
. The main characteristics for each
configuration mode are listed below.
#FF
FOR EACH RISER
#II
FOR EACH FLOOR
CAN SYSTEM CONFIGURATION MODE 1 BE
USED?
≤ 20
≤4
YES,
but it is necessary to calculate the total num-
ber of handsets for whole system according to
Mode 1 configuration. If the total number cal-
culated is 4000 or less, Mode 1 configuration
is possible, if the total number is over 4000,
Mode 2 must be considered.
> 20
≤ 4
NO
≤20
> 4
NO
> 20
> 4
NO
MODE 2 example
For example: if the highest building of a project has 25 floors, and the max. number
of apartment for floor is 8, with 15 risers in total. Then for mode 2, the #FF should be
25, while #II should be 8. Make the calculations according to following table to judge if
mode 2 configuration can be used.
#FF FOR EACH
RISER
#II FOR EACH
FLOOR
TOTAL RISER
CAN SYSTEM CONFIGURA-
TION MODE 2 BE USED?
25
8
15
25*8*15=3000
3000<4000
30 - 25*8*30=6000
6000>4000
Rear view
BT00466-b-en
30/05/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...