184
322040
Audio indoor handset
Configuration
how to enter in installation setup status
:
with the handset in stand-by, long press the door lock release pushbutton until a long
beep is heard. Connection status LED must be off.
FUNCTIONS
OPErATION
rEMArkS
Enter the room number setup submenu
While in the initial installation setup status press and hold down the switchboard pushbutton once to enter
the household number setup submenu. Note: the first number to set after entering the submenu is the
thousand position.
Household number range is 101-9999. Default
number is 101.
The two numbers after 101 cannot be higher
than the number of households per floor.
Set the parameter
Press the switchboard pushbutton to add 1 unit to the relevant position. If the pushbutton is pressed after
the input parameter has reached 10, 3 short beeps will indicate wrong operation and the device will exit the
household number setup submenu automatically and return to the initial installation setup status.
Select the setting and exit the setup
submenu
Press the door lock release pushbutton to move to next setting position, the order is: thousands, hundreds,
tens and units. Note:
1) If no number is entered in a position, the default 0 will apply.
2) After setting the units position press the door lock release key to exit household number setup and return to
the initial installation setup status. If the household number is set correctly, a long beep will be heard when
exiting the menu, and the number will be saved; otherwise, 3 short beeps will be heard and the number will
be not saved
Exit
1) Press the door lock release pushbutton to move to the last item. Press the door lock release pushbutton
again to exit household number setup and return to the initial installation setup status.
2) If the operation is performed wrongly, 3 short beeps will be heard the unit will automatically return to the
initial installation setup status.
Example 1
:
If the room number must be set to 403, then the relative parameter should be:
0 for thousands, 4 for hundreds, 0 for tens and 3 for units.
While in the initial installation setup status press and hold down the switchboard
pushbutton once to enter the household number setup submenu.
The current position is thousands. Since the parameter for thousands is 0, press the door
lock release pushbutton to move to the hundreds position.
The parameter for the hundreds is 4, press the switchboard pushbutton 4 times, then
press door lock release pushbutton to move to the tens. Since the parameter for tens is
0, there no need to press the switchboard pushbutton, just press the door lock release
pushbutton to move to the units. Since the parameter for the units is 3, press the
switchboard pushbutton 3 times. Then press the door lock release key to return to the
initial installation setup status and check at the same time if the settings entered are
correct. If they are correct, 1 long beep will be heard. Otherwise 3 short beeps will be
heard. Once in the initial installation setup status press and hold the door lock release
pushbutton to exit setup status and return to standby status.
Set installation parameters - room number (FFII):
BT00471-b-en
30/05/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...