10 Pushbuttons colour video entrance panel
Legend
1.
Switch (ON - OFF) - enable/disable anti removal (tamper) function
2.
SPK : loudspeaker volume adjust
3.
MIC : microphone volume adjust
4.
Status jumper socket
5.
RJ45 system BUS connector
6.
4 poles connector (GND /DAS/LOCK-/LOCK+). GND/DAS = electrical door lock status
connector - LOCK-/LOCK+ = electrical door lock connector
7.
RJ45 additional pushbuttons panel connector
8.
Mode jumper socket
9.
ISP : entrance panel software upgrade connector
10.
Room number reset/door lock status setting pushbutton
11.
Configurations socket
12.
DIP-SWITCH for video gain setting - see specific section
13.
Anti-thief switch
14.
VIDEO-IN/GND/NC/+12V/LED : entrance panel camera and compensation lamp
connector
Entrance panel status setting
Configuration
Two different configuration ways available:
Configuration by inserting phisical configurators -
WAY 1
Configuration by using SF2 software and PC connection -
WAY 2
Entrance panel have two status, one is work status, another is setting status.
In
work status
, entrance panel can call internal unit and work with internal unit.
Entrance panel usually is in this status.
In
setting status
, entrance panel can’t call and work with internal unit,but can set
room number or SCS address of corresponding pushbutton.
After finished set, exit setting status by jumper insertion (NA).
By inserting jumper (NA), entrance panel is in work status. By inserting jumper (CF),
entrance panel is in setting status.
Call mode
D45 system have two call modalities, one is
room number mode
, another is
SCS ad-
dress mode
(direct call mode). In room number mode, internal unit can be set accord-
ing to the room number; visitor type room number in entrance panel to call resident.
Factory default is in room number mode.
In SCS address mode (direct call mode),internal unit can be set according to SCS ad-
dress. Visitor just type SCS address to call resident, for example just type 1.
For pushbuttons entrance panel, must be defined each pushbutton math a room
number or SCS address.
Rear view
Configuration define in setting status
as for below table:
Configuration define in work status
as for below table:
rOOM NUMBEr MODE
SCS ADDrESS MODE
#I#I
maximum apartment quantity per floor
Don’t use
FF
floor number of corresponding pushbutton
SCS address high digit of corresponding
pushbutton
II
apartment number corresponding
pushbutton
SCS address low digit of corresponding
pushbutton
DEFINE
NN
Entrance panel number
FF
Don’t use
II
Don’t use
BT00765-a-en
03/06/2013
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...