Riser shunt
Configuration
Device must be configured
for following parameters:
Configuration settings by inserting phisical configurators - WAY 1 :
Phisical connection for the configurators to their sockets
Configuration examples :
Example (A)
:
The number of riser shunts is 5, each riser has 20 floors, and each floor has 4 handsets.
The Switchboard that can be called directly by this riser is no. 2. System configuration
mode 1 is used. The riser shunt configuration should be as follows:
NNNN :
Number of riser shunts
#FF
: Floor quantity in a riser
#II
: Maximum apartments quantity per floor in a riser
C
: The switchboard number which is the first priority for this Riser.
If the number of switchboard is higher than 9 (from 10 to 15), this parameter
can only be set by riser shunt pushbuttons or by system configuration tool
software interface.
M
: System configuration mode. If you choose MODE 1 or MODE 2 configuration
way, this parameter is 0. If you set 2, it means this riser shunt is used inside
riser to extend the maximum number of IUs (from 400 IUs to 800 IUs)
Two different configuration modes available for whole system:
configuration
MODE 1
and configuration
MODE 2
. The main characteristics for each
configuration mode are listed below.
When the biggest number of #FF in whole system is ≤ 20, and the biggest number of
#II is ≤4, and the total risers number is ≤ 50, we recommend to choose (
MODE 1
)
configuration for system.
When the biggest number of #FF in whole system is more than 20, or the biggest
number of #II is more than 4, we suggest to use (
MODE 2
) configuration to setup #FF
(choose the biggest number #FF of system) and #II (choose the biggest number #II of
system), then calculate total IU number of system. If the total number (#FF * #II * R ) is
less or equal 4000, use of (
MODE 2
) is suggested.
Two different device configuration ways available :
WAY 1
) Configuration settings by inserting phisical configurators
WAY 2
) Configuration by using SF2 Software and PC connection
POSITION MODE 1
MODE 2
CF1
NNNN
NNNN
CF2
CF3
CF4
CF5
#FF is 20(default).
No need for configuration
#FF
(#II setup using same value for all
system riser shunts).
CF6
CF7
#II is 4(default).
No need for configuration
#II
(#II setup using same value for all
system riser shunts).
CF8
C
C
C
M
M
M
POSITION MODE 1 vAlUE FOr CONFIgUrATOr rEMArkS
CF1
N
0
0 no config needed
CF2
N
0
0 no config needed
CF3
N
0
0 no config needed
CF4
N
5
CF5
#F
#FF is 20(default).
No need for configuration
CF6
#F
CF7
#I
#II is 4(default).
No need for configuration
CF8
#I
C
C
2
M
M
0
0 no config needed
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...