228
S2
S1
C F G
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
POWER
+
-
SYST EM
IN
OUTPUT1
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
SYSTEM
OUT
OUTPUT8
OUTPUT7
OUTPUT6
POWER L1
L2
ISP
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
323017
S2
S1
C F G
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
POWER
+
-
SYST EM
IN
OUTPUT1
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
SYSTEM
OUT
OUTPUT8
OUTPUT7
OUTPUT6
POWER L1
L2
ISP
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
323017
S2
S1
C F G
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
POWER
+
-
SYST EM
IN
OUTPUT1
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
SYSTEM
OUT
OUTPUT8
OUTPUT7
OUTPUT6
POWER L1
L2
ISP
C
F
1
C
F
2
C
F
3
C
F
4
C
F
5
C
F
6
C
F
7
M
323017
141 mm
105 mm
128,2 mm
94 mm
33 mm
8
7
6
10
13
14
15
9
1
2
3
4
5
12
11
25/11/2013
BT00792-a-
323017
D45 System
Front view
Lower view
Lift control interface
Description
Legend
Dimensional data
1.
Configurators housing
2.
Serial interface connector for PC configuration and firmware update
3.
Relay
OUTPUT 8
(connect to the corresponding key of lift)
4.
Relay
OUTPUT 7
(connect to the corresponding key of lift)
5.
Relay
OUTPUT 6
(connect to the corresponding key of lift)
6.
Relay
OUTPUT 5
(connect to the corresponding key of lift)
7.
Relay
OUTPUT 4
(connect to the corresponding key of lift)
8.
Relay
OUTPUT 3
(connect to the corresponding key of lift)
9.
Relay
OUTPUT 2
(connect to the corresponding key of lift)
10.
Relay
OUTPUT 1
(connect to the corresponding key of lift)
11.
L1 - L2 Lift control status LEDs (see specific section)
12.
S1 - S2 Manual device configuration pushbuttons
(NOT USED)
13.
RJ45 System OUT connection
14.
RJ45 System IN connection
15.
Auxiliary power supply input connector (30V)
Lift control device suitable to interface D45 VDE system with the building elevator
system in order to control the lift call to the floor directly from the apartment internal
unit. Device must be configured.
NOTE : INSTALLATION AND CONNECTIONS MUST BE ALWAYS PERFORMED
ACCORDINGLY TO THE ELEVATOR MANUFACTURER SPECIFICATION
.
Technical data
Power supply:
30 Vdc
Stand by current absorption:
< 15 mA @ 30 V
Max. operating current absorption:
< 30 mA @ 30 V
Stand by power consumption:
0.45 W
Operating power consumption:
0.9 W
Operating temperature:
(-10)-(+40)°C
en
Summary of Contents for D45 SYSTEM
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...GENERAL FEATURES...
Page 36: ......
Page 37: ...GENERAL RULES FOR INSTALLATION...
Page 82: ......
Page 83: ...WIRING DIAGRAMS...
Page 102: ......
Page 103: ...WIRING DIAGRAMS VARIANTS...
Page 116: ......
Page 117: ...CATALOGUE...
Page 122: ......
Page 123: ...TECHNICAL SHEETS...